DataSheet26.com

NCS1S1205SC PDF даташит

Спецификация NCS1S1205SC изготовлена ​​​​«Murata» и имеет функцию, называемую «Isolated 1W 4:1 Input Single Output DC/DC Converters».

Детали детали

Номер произв NCS1S1205SC
Описание Isolated 1W 4:1 Input Single Output DC/DC Converters
Производители Murata
логотип Murata логотип 

8 Pages
scroll

No Preview Available !

NCS1S1205SC Даташит, Описание, Даташиты
www.murata-ps.com
FEATURES
„UL 60950 recognised
„4:1 Wide range voltage input
„Operating temperature range -40°C to
105°C with derating
„1kVDC Isolation “Hi Pot Test”
„3.3V, 5V & 12V outputs
„No electrolytic capacitors
„Continuous short circuit protection
PRODUCT OVERVIEW
The NCS1 series of DC/DC converters offers a
single output voltage from input voltage ranges
of 4.5-18V and 9-36V. The NCS1 is housed in an
industry standard package with a standard pinout.
Applications include telecommunications, battery
powered systems, process control and distributed
power systems.
NCS1 Series
Isolated 1W 4:1 Input Single Output DC/DC Converters
SELECTION GUIDE
Order Code
Input
Voltage
Output
Voltage
Output
Current
Efficiency
5V or 24V Input.
Nom.
VV
Min. Typ.
mA % %
NCS1S1203SC 12 3.3 303 73 77
NCS1S1205SC 12
5 200 76 79
NCS1S1212SC 12 12 83 75 78
NCS1S2403SC 24 3.3 303 76 78.5
NCS1S2405SC 24
5 200 79 82
NCS1S2412SC 24 12 83 80 83
Efficiency
12V Input.
Min. Typ.
%%
71 75
74 77
75 79
73 76
77 80
77 80
Ripple and Noise
Typ.
mVp/p
24
25
40
35
27
28
Max.
mVp/p
70
50
120
70
50
120
pF
24
30
35
28
42
42
MTTF1
kHrs
1020
915
1130
1217
1022
943
INPUT CHARACTERISTICS
Parameter
Conditions
Voltage range
12V input types
24V input types
Input current
NCS1S12XX
NCS1S24XX
Input reflected ripple
current
NCS1S12XX
NCS1S24XX
5V input voltage
12V input voltage
12V input voltage
24V input voltage
Min. Typ. Max. Units
4.5 12 18
9 24 36
V
0.26
0.1
A
0.1
0.05
5 30
mA p-p
5 15
OUTPUT CHARACTERISTICS
Parameter
Conditions
Min. Typ. Max. Units
Rated power
All output types
1W
Minimal load to meet datasheet specification
10 %
Voltage set point accuracy All output types
±1 ±2 %
Line regulation
Low line to high line
±0.5 %
Load regulation
All output types
0.5 %
Transient response
Peak deviation (12.5-37.5% & 37.5-12.5% swing)
Settling time
(within 5% Vout Nom.)
5 %Vout
2 ms
ISOLATION CHARACTERISTICS
Parameter
Conditions
Isolation test voltage
Flash tested for 1 second
Resistance
Viso = 1kVDC
Min. Typ. Max. Units
1000 VDC
1 GΩ
GENERAL CHARACTERISTICS
Parameter
Conditions
Min. Typ. Max. Units
Switching frequency
100 400 kHz
Control pin input
Module on, pin unconnected or open collector floating
Module off
0.8 V
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
1 Calculated using MIL-HDBK-217 FN2, parts stress method with nominal input voltage at full load.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
All enquiries: www.murata-ps.com/support
KDC_NCS1.D01 Page 1 of 8









No Preview Available !

NCS1S1205SC Даташит, Описание, Даташиты
NCS1 Series
Isolated 1W 4:1 Input Single Output DC/DC Converters
TEMPERATURE CHARACTERISTICS
Parameter
Operation
Storage
Case temperature rise above ambient
Conditions
100% Load, Nom VIN, Still Air
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection (for SELV input voltages)
Control pin input voltage
Lead temperature 1.0mm from case for 10 seconds (to JEDEC JESD22-B106 ISS C)
Input voltage, NCS1 12V input types
Input voltage, NCS1 24V input types
APPLICATION NOTES
Maximum Output Capacitance
Maximum output capacitance should not exceed:
Output Voltage
V
3.3
5
12
Maximum Load Capacitance
μF
470
470
220
Min. Typ. Max. Units
-40 105
-50 125 °C
15 22
Continuous
18V Max
260°C
25V
40V
Start-up times
Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product series will
start into the maximum output capacitance with increased start times.
Part No.
NCS1S1203SC
NCS1S1205SC
NCS1S1212SC
NCS1S2403SC
NCS1S2405SC
NCS1S2412SC
Start-up times
ms
6
9
20
12
7
12
Control Pin
The NCS1 converters have a shutdown feature which enables the user to put the converter into a low power state. The control pin connects directly to the base of an internal
transistor, and the switch off mechanism for the NCS1 works by forward biasing this NPN transistor. If the pin is left open (high impedance), the converter will be ON (there is
no allowed low state for this pin), but once a control voltage is applied with sufficient drive current, the converter will be switched OFF. A suitable application circuit is shown
below.
V
IN
V
C
OV
-V
IN
R
1
NCS1
D
1 CTRL
R
2
Q1
D (e.g. 1N4003) is required to provide high impedence when the signal is
1
low. From the NCS1 specification, the drive current to operate this function is
recommended to be 3mA, and hence the value of R can be derived as follows:
1
V -V -V
R=
1
CD
I
Q
C
Assuming V =5V, V =0.7V and V =1V:
CD
Q
R=
1
5
- 0.7 - 1.0
3 x 10-3
=
1100Ω
www.murata-ps.com
All enquiries: www.murata-ps.com/support
KDC_NCS1.D01 Page 2 of 8









No Preview Available !

NCS1S1205SC Даташит, Описание, Даташиты
NCS1 Series
Isolated 1W 4:1 Input Single Output DC/DC Converters
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NCS1 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The NCS1 has been recognized by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V
peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system.
The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier
must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according
to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The NCS1 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
SAFETY APPROVAL
The NCS1 series has been recognized by Underwriters Laboratory (UL) to UL 60950 for functional insulation to a maximum case temperature of 105°C. File number E151252
applies.
The NCS1 Series of converters are not internally fused so to meet the requirements of UL 60950 an anti-surge input line fuse should always be used with ratings as defined below.
NCS1S12xxSC: 1A
NCS1S24xxSC: 0.5A
All fuses should be UL approved and rated to at least the maximum allowable DC input voltage.
RoHS COMPLIANCE INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260ºC for 10 seconds. The pin termination finish
on this product series is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The series is backward compatible with Sn/Pb soldering
systems.
CHARACTERISATION TEST METHODS
Ripple & Noise Characterisation Method
Ripple and noise measurements are performed with the following test configuration.
C1 1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter
C2
10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less
than 100mΩ at 100 kHz
C3 100nF multilayer ceramic capacitor, general purpose
R1 450Ω resistor, carbon film, ±1% tolerance
R2 50Ω BNC termination
T1 3T of the coax cable through a ferrite toroid
RLOAD
Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires
Measured values are multiplied by 10 to obtain the specified values.
Differential Mode Noise Test Schematic
SUPPLY
DC/DC Converter
++
Input Output
--
C1 C2 C3 R1
OSCILLOSCOPE
T1 R2
Y INPUT
www.murata-ps.com
R LOAD
All enquiries: www.murata-ps.com/support
KDC_NCS1.D01 Page 3 of 8










Скачать PDF:

[ NCS1S1205SC.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
NCS1S1205SCIsolated 1W 4:1 Input Single Output DC/DC ConvertersMurata
Murata

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск