DataSheet26.com

даташит DMT10-2-1111 PDF ( Datasheet )

DMT10-2-1111 Datasheet Download - SICK

Номер произв DMT10-2-1111
Описание LONG RANGE DISTANCE SENSORS
Производители SICK
логотип SICK логотип 



1Page
		

No Preview Available !

DMT10-2-1111 Даташит, Описание, Даташиты
DMT10-2-1111
DMT
LONG RANGE DISTANCE SENSORS







No Preview Available !

DMT10-2-1111 Даташит, Описание, Даташиты
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
DMT10-2-1111 | DMT
LONG RANGE DISTANCE SENSORS
Ordering information
Model name
DMT10-2-1111
Other models and accessories www.sick.de/DMT
Part no.
1027603
Detailed technical data
Performance
Measuring range
Resolution
Repeatability
Accuracy
Response time
Cycle time
Average depth
Output time
Aperture delay time
Light source
Laser class
Typ. light spot size (distance)
Note
Special characteristic
0,5 m ... 155 m, 90 % remision
0,5 m ... 65 m, 18 % remission
0,5 m ... 40 m, 6 % remission
≤ 1 mm
7 mm 1) 2)
10 mm 3) 2)
± 10 mm 4) 5)
1 ms ... 4.000 ms 6)
1,024 per sec.
1/16/64/256/1,024
1 ms ... 4.000 ms 7)
≥ 1 s 7)
Laser, infrared
1 (EN 60825-1:Nov.2001, IEC 60825-1:ÄM2:2001)
20 mm (+ 5 x distance in m)
Mechanical aperture
Mechanical aperture
1) Dependant on distance and remission, 7 mm, at 6 % ... 90 % remission from 0.5 m ... 65 m, at 6 % ... 18 % remission from 0.5 m ... 40 m, at 6 % remission from
0.5 m ... 15 m.
2) Environmental conditions constant, min. warm-up time 30 min, average depth 1,024, statistical error 1 σ.
3) Dependant on distance and remission, 10 mm, at 6 % ... 90 % remission from 60 m ... 155 m, at 6 % ... 18 % remission from 40 m ... 65 m, at 6 % remission from
15 m ... 40 m.
4) 23 °C air temperature, 977 hPa, min. warm-up time 30 min.
5) When operating in ambient temperatures between +40 °C ... +55 °C the accuracy can decrease by factor 2.5.
6) Dependant on average setting, average depth, timeout, baud rate, data output, output format and effective dead time of aperture.
7) Dependant on average setting, average depth, timeout, baud rate, data outpu and output format.
Interfaces
Analog output
Switching output
4 mA ... 20 mA, scalable
Q1, Q2 1)
1) Output Q short-circuit protected.
2) Switchable.
2 DISTANCE SENSORS | SICK
Online data sheet | 2015-03-12 15:56:44
Subject to change without notice







No Preview Available !

DMT10-2-1111 Даташит, Описание, Даташиты
DMT10-2-1111 | DMT
LONG RANGE DISTANCE SENSORS
Data interface
Interface for parametrization
RS-422, RS-232 2)
RS-232
1) Output Q short-circuit protected.
2) Switchable.
Mechanics/electronics
Supply voltage Vs
Ripple
Power consumption
Initialization time
Connection type
Weight
Output current IA
DC 18 V ... 30 V, limit values
< 5 Vpp 1)
≤ 6 W 2)
6 s
1 x cable gland, 1 x Sub-D, 9-pin
Approx. 1.200 g
100 mA
1) May not fall short of or exceed VS tolerances.
2) Without load.
Ambient data
Enclosure rating
Protection class
Electromagnetic compatibility (EMC)
Ambient temperature
Temperature drift
Mechanical load
IP 65
III 1)
EN 55011:1998 Kl. B, Gr.1
EN 61000-6-2
Operation: –10 °C ... +55 °C
Operation with cooling case: –10 °C ... +75 °C
Storage: –25 °C ... +70 °C
Typ. 0,6 mm/K 2)
Typ. 0,3 mm/K 3)
Shock: (IEC 60068-2-27, –2-29)
Sine: (IEC 60068-2-6)
1) Reference voltage DC 50 V PELV-voltage (EN 50178)
2) -10° C ... 0° C, +40 °C ... +55 °C.
3) 0 °C ... +40 °C.
2015-03-12 15:56:44 | Online data sheet
S ubject to change without notice
DISTANCE SENSORS | SICK
3










Всего страниц 7 Pages
Скачать PDF[ DMT10-2-1111.PDF Даташит ]

Ссылка Поделиться


Related Datasheets

Номер в каталогеОписаниеПроизводители
DMT10-2-1111LONG RANGE DISTANCE SENSORSSICK
SICK
DMT10-2-1113LONG RANGE DISTANCE SENSORSSICK
SICK

Номер в каталоге Описание Производители
6MBP200RA-060

Intelligent Power Module

Fuji Electric
Fuji Electric
ADF41020

18 GHz Microwave PLL Synthesizer

Analog Devices
Analog Devices
AN-SY6280

Low Loss Power Distribution Switch

Silergy
Silergy

DataSheet26.com    |    2019    |   Контакты    |    Поиск