No Preview Available ! SI-8001FDE Hoja de datos, Descripción, Manual

SI-8001FDE
DC-to-DC Step-Down Converter
Features and Benefits
3.5 A output current supplied in a small, surface mount
power package
High efficiency: 83% at VIN= 15 V, IO= 2.0 A,VO= 5 V
Requires only six external components (optional soft
start requires an additional capacitor)
Oscillation circuit built-in (frequency 300 kHz typical)
Constant-current mode overcurrent protection circuit and
overtemperature protection circuit built-in
Soft start function built-in (can be implemented as an
on/off function; output-off state at low level)
Low current consumption during output-off state
Package: TO263-5
Description
The SI-8001FDE DC voltage regulator is a DC-to-DC buck
convertor that attains an oscillation frequency of 300 kHz,
and has an integrated miniaturized choke coil, allowing it to
serve as a small, high efficiency power supply in a compact
TO263 package.
The internal switching regulator function provides high
efficiency switching regulation without any need for adjustment.
The device requires only six external support components. The
optional soft start function requires an additional capacitor.
Optional on/off control can be performed using a transistor.
The SI-8001FDE includes overcurrent and overtemperature
protection circuits.
Applications include:
DVD recorder
FPD TV
Telecommunications equipment
Office automation equipment, such as printers
On-board local power supply
Output voltage regulator for second stage of SMPS
(switched mode power supply)
Not to scale
Functional Block Diagram
VIN 1 IN
C1
PReg
Overcurrent
Protection
SW 2
L1
Di
SPB-G56S
(Sanken)
VOUT
C2
5 SS On/Off
Soft Start
C3
Reset
Osc
Comparator
Error
Amplifier
Latch and
Driver
Overtemperature
Protection
ADJ 4
R1
R2
GND
3
Reference
Voltage
27469.056-I

1 page




SI-8001FDE pdf
SI-8001FDE
DC-to-DC Step-Down Converter
Thermal Performance Characteristics
The application must be designed to ensure that the TJ(max)
of the device is not exceeded during operation. To do so, it is
necessary to determine values for maximum power dissipation,
PD(max), and ambient temperature, TA(max).
The relationships of TJ, PD, TA, and case temperature, TC, are as
shown in the following formulas:
PD =
TJ – TC
RθJC
and
PD =
TJ – TA
RθJA
PD can be calculated from input values:
.
where:
PD
= VO
I
O
⎜⎜⎝⎛
100
Hx
1⎟⎟⎠⎞
VF
I
O
⎜⎜⎝⎛1
VO
VIN
⎟⎟⎠⎞
VO is output voltage in V,
VIN is input supply voltage in V,
IO is output current in A,
ηx is IC efficiency in percent (varies with VIN and IO; refer to
efficiency performance curves for value), and
VF is forward voltage for the input diode, Di. In these tests, the
Sanken SPB-G56S was used, at 0.4 V. For application design,
obtain thermal data from the datasheet for the diode.
PD is substantially affected by the heat conductance properties of
the application, in particular any exposed copper area on the PCB
where the device is mounted. The relationships of PD, TA, and
copper area is represented in the Power Dissipation chart.
RθJA for a given copper area can be determined form the Device
Thermal Resistance chart. This can be substituted into the formula
above to determine the TJ (max) allowable in the application.
Generally, more than 10% to 20% derating is required.
Because the heat dissipation capacity of the copper area depends
substantively on how it is used in the actual application, thermal
characteristics of the application must be confirmed by testing.
TC is determined by connecting a thermocouple to the device as
shown here:
Thermocouple mount
at tab center
Power Dissipation versus Ambient Temperature
TJ(max) = 125°C; Mounted on glass-epoxy PCB (40 mm × 40 mm),
with varying exposed copper areas
3.5
Cu Area: 1600 mm2
RθJA = 33.3°C/W
3.0
Cu Area: 800 mm2
RθJA = 37°C/W
2.5
2.0
Cu Area: 400 mm2
RθJA = 44°C/W
Cu Area: 100 mm2
1.5 RθJA = 53°C/W
1.0
0.5
0
–25
0
25 50 75 100 125
TA (°C)
Device Thermal Resistance versus Exposed Copper Area on PCB
Glass-epoxy PCB, 40 mm × 40 mm
55
50
45
40
35
30
0
200 400 600 800 1000 1200 1400 1600 1800
Copper Area (mm2)
6
Overtemperature
Protection:
Output Voltage versus
Junction Temperature
VIN = 15 V, IO = 10 mA
5
4
3
2
OTP On
And analyzing the results using the following formula:
TJ = PD × RθJC + TC ,
for this device, RθJC is 3 °C/W.
1
OTP Off
0
0 20 40 60 80 100 120 140 160 180
TJ (°C)
Sanken Electric Co., Ltd.
3-6-3 Kitano, Niiza-shi, Saitama-ken
352-8666, Japan
Phone:+81-48-472-1111
http://www.sanken-ele.co.jp
5

5 Page





SI-8001FDE arduino
SI-8001FDE
DC-to-DC Step-Down Converter
Application and operation examples described in this document are quoted for the sole purpose of reference only, for the use of the products
herein, and Sanken can assume no responsibility for any infringement of industrial property rights, intellectual property rights, or any other rights
of Sanken or any third party which may result from its use.
When using the products herein, the applicability and suitability of such products for an intended purpose or object shall be reviewed at the
user’s responsibility.
Although Sanken undertakes to enhance the quality and reliability of its products, the occurrence of failure and defect of semiconductor prod-
ucts at a certain rate is inevitable. Users of Sanken products are requested to take, at their own risk, preventative measures including safety design
of the equipment or systems against any possible injury, death, fires or damages to the society due to device failure or malfunction.
Sanken products listed in this document are designed and intended for the use as components in general purpose electronic equipment or appa-
ratus (home appliances, office equipment, telecommunication equipment measuring equipment, etc.). Before placing an order, the user’s written
consent to the specifications is requested.
When considering the use of Sanken products in the applications where higher reliability is required (transportation equipment and its control
systems, traffic signal control systems or equipment, fire/crime alarm systems, various safety devices, etc.), please contact your nearest Sanken
sales representative to discuss and obtain written confirmation of your specifications.
The use of Sanken products without the written consent of Sanken in the applications where extremely high reliability is required (aerospace
equipment, nuclear power control systems, life support systems, etc.) is strictly prohibited.
Anti radioactive ray design is not considered for the products listed herein.
If there is any discrepancy between English and Japanese versions of this datasheet, the Japanese version should take precedence over the
English one.
Please accept in advance that the content of this datasheet is subject to change without notice for the purpose of such as improvement of the
product.
Copyright © 2007 Sanken Electric Co., Ltd.
This datasheet is based on Sanken datasheet SSJ-03222
Sanken Electric Co., Ltd.
3-6-3 Kitano, Niiza-shi, Saitama-ken
352-8666, Japan
Phone:+81-48-472-1111
http://www.sanken-ele.co.jp
11

11 Page







PáginasTotal 13 Páginas
PDF Descargar[ Datasheet SI-8001FDE.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
SI-8001FDEDC-to-DC Step-Down ConverterSanken
Sanken
SI-8001FDESeparate Excitation Step-down Switching ModeETC
ETC

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar