Service Menu 
FOR O2 CALIBARTION SENSOR MUST
OPERATE CONTINOUSLY FOR AN HOUR TO
ENSURE STABLE READINGS
O2 Calibration Menu
(Press 2)
Displays: O2
Zero Point Set
(Press 1)
Displays: Cal, 1111 on Complete
APPLY N2 FOR 2 MINUTES
BEFORE ZP SET
Span Point Set
(Press 2)
Displays: Cal, 1111 on Complete
ALLOW AMBIENT OPERATION 2
MINUTES BEFORE SP SET
Span Point Set
(Press 1-2 Simultaneously)
Displays: Heater Voltage, 1111 on Complete
SET USING BUTTON 1 & 2 TO
INCREMENT/DECREMENT. PRESS
BUTTON 3 TO SAVE
131 Business Center Drive Suite A3, Ormond Beach, FL  32174 
TEL: 877.678.4259  | FAX: 866.422.2356 
EMAIL: [email protected] | www.co2meter.com 
Enter Service Menu
(Press 1, 2, 3)
Displays: 1111
4-20mA CALIBARTION SHOULD BE DONE WITH
A MULTIMETER & A SENSE RESISTOR CLOSE
TO EXPECTED LOAD
WARNING: FACTORY USE ONLY
4-20mA Calibration Menu
(Press 2)
Displays: 420
Zero Point Set
(Press 1)
Displays: 420 CALVAL, 1111 on Complete
SET USING BUTTON 1 & 2 TO INCREMENT/
DECREMENT. PRESS BUTTON 3 TO SAVE
METER SHOULD READ 0mA, or as close as
possible.
Span Point Set
(Press 2)
Displays: 420 CAL VAL, 1111 on Complete
SET USING BUTTON 1 & 2 TO INCREMENT/
DECREMENT. PRESS BUTTON 3 TO SAVE
METER SHOULD READ 20mA, or as close as
possible.
Span Point Set
(Press 1-2 Simultaneously)
Displays: Heater Voltage, 1111 on Complete
UNIT WILL LOOP THROUGH VALUES.
Pressing 3 at any time will go back a menu. Ensure that after you have completed any service operations you press 3 to return back to measurement
mode. Leaving the unit with 1111 on the display will not result in updated output.
 
Manual 
  Revision 1.0  March 2012 
  5 

5 Page










PáginasTotal 5 Páginas
PDF Descargar[ Datasheet TR250Z.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
TR250-080(TR250-xxx) PolySwitch Resettable DevicesTyco Electronics
Tyco Electronics
TR250-080TPOLYSWITCHTyco Electronics
Tyco Electronics
TR250-080TPOLYSWITCHTyco Electronics
Tyco Electronics
TR250-080UPolySwitch PTC Devices Overcurrent Protection DeviceTyco Electronics
Tyco Electronics

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar