DataSheet26.com

3UA6200-2X PDF даташит

Спецификация 3UA6200-2X изготовлена ​​​​«Siemens» и имеет функцию, называемую «Overload Relays».

Детали детали

Номер произв 3UA6200-2X
Описание Overload Relays
Производители Siemens
логотип Siemens логотип 

2 Pages
scroll

No Preview Available !

3UA6200-2X Даташит, Описание, Даташиты
HP Rated Control
Overload Relays______
,!> f- rs
>HP Rated starters are priced and
istocked less the overload relays. The
overload relays can be ordered sepa-
rately for field installation or they can be
factory installed.
Factory Installed Overload Relay:
A) Select the appropriate overload relay
from the chart below. Then add the
two digit suffix number (shown bold
below) of the overload relay to the
starter Catalog Number. See exam-
ple shown. If the motor FLA is not
known, refer to Application Data
Section for a typical value.
B) Add the price of the overload relay to
the starter price to obtain the com-
plete list price.
Example: Th Hp at 460 volts, 1800
RPM, 9.7 FLA The starter Catalog
Number would be SXLHB1460 The over-
load relay would be a 3UA5000-1K Add
the suffix "IK" to the end of the starter
Catalog Number SXLHB14601K $238.00
+ $72.00 = $310.00 Total List Price.
Selection
Type "3UA" Overload Relay Setting
Instructions:
For motors with a service factor of
1.00, multiply motor nameplate full load
current (FLA) by 0.92 and set overload
relay dial to that value.
For motors with a service factor of
1.15, with a marked temperature rise
not exceeding 40°C, set dial to full load
current marked on motor nameplate.
HP Rated
Starter Size®
HA
HB
>
HC
HD
HE
Overload Relay
Setting Ranges
In Amperes
0.1-0.16
0.16-0.25
0.25-0.4
0.4-0.63
0.63-1
0.8-1.25
1-1.6
1.25-2
1.6-2.5
2-3.2
2.5-4
3.2-5
4-6.3
2-8
6.3-10
8-12.5
10-14.5
0.1-0.16
0.16-0.25
0.25-0.4
0.4-0.63
0.63-1
0.8-1.25
1-1.6
1.25-2
1.6-2.5
2-3.2
2.5-4
3.2-5
4-6.3
5-8
6.3-10
8-12.5
10-16
12.5-20
16-25
0.10-0.16
0.16-0.25
0.25-0.40
0.40-0.63
0.63-1.00
0.80-1.25
1-1.6
1.25-2
1.6-2.5
2-3.2
2.5-4
Overload Relay For
Full Voltage Starters
HP Rated Type Only
3UA50 00-OA
3UA50 00-OC
3UA50 00-OE
3UA50 00-OG
3UA50 00-OJ
3UA50 00-OK
3UA50 00-1A
3UA5000-1B
3UA50 00-1 C
3UA5000-1D
3UA50 00-1E
3UA50 00-1F
3UA50 00-1G
3UA500Q-1H
3UA50 00-1J
3UA5000-1K
3UA50 00-2S
3UA52 00-OA
3UA52 00-OC
3UA52 00-OE
3UA52 00-OG
3UA52 00-OJ
3UA52 00-OK
3UA52 00-1A
3UA52 00-1B
3UA5200-1C
3UA52 00-10
3UA5200-1E
3UA52 00-1F
3UA5200-1G
3UA52 00-1H
3UA52 00-1 J
3UA52 00-1K
3UA52 00-2A
3UA52 00-2B
3UA52 00-2C
3UA55 00-OA
3UA55 00-OC
3UA55 00-flE
3UA55 00-06
3UA55 00-OJ
3UA55 00-flK
3UA55 00-1A
3UA55 00-1B
3UA5500-1C
3UA55 00-10
3UA5500-1E
©Note the maximum UL operating current of the starter.
®To be used with size HH and HJ starters only.
©Panel mounting must be used for setting ranges above
135 to 160 A in order to prevent overheating. Use
3UX1221 links for connectionto the 3TF52 contactor
see page 258.
Price $
72.
72.
78.
HP Rated
Starter Size®
HE
HG
HH
HJ
HL
HN
HR
HT
Overload Relay
Setting Ranges
In Amperes
3.2-5
4-6.3
5-8
6.3-10
8-12.5
10-16
12.5-20
16-25
20-32
25-36
16-25
20-32
25-40
32-50
40-57
50-63
57-70
63-80®
70-88®
55-88
63-90
80-110
90-120
110-135
55-80
63-90
80-110
90-120
110-135
120-150
135-160®
150-180®
80-125
125-200
160-250
200-320
250-400
Overload Relay For
Full Voltage Starters
HP Rated Type Only
3UA5500-1F
3UA5500-1G
3UA5500-1H
3UA55 00-1J
3UA5500-1K
3UA55 00-2A
3UA55 00-2B
3UA55 00-2C
3UA55 00-2D
3UA55 00-2Q
3UA58 00-2C
3UA58 00-20
3UA58 00-2E
3UA58 00-2F
3UA58 00-2T
3UA58 00-2P
3UA58 00-2V
3UA58 00-2U
3UA58 00-2W
3UA60 00-2H
3UA60 00-2W
3UA60 00-2X
3UA60 00-3H
3UA60 00-3J
3UA62 00-2H
3UA62 00-2W
3UA62 00-2X
3UA62 00-3H
3UA62 00-3J
3UA62 00-3K
3UA62 00-3L
3UA62 00-3M
3UA66 00-2K
3UA66 00-3B
3UA66 00-3C
3UA66 00-30
3UA66 00-3E
Price $
78.
117.
215.
215.
969.
$
a3j 0m2
»a. >i
O at
O =3
3 Q-
15
Discount Code: Overload Relays
Siemens Industrial Control Products
<fsr>
/









No Preview Available !

3UA6200-2X Даташит, Описание, Даташиты
HP Rated Control
Technical Data
Technical
Size HT
HP Rated Key Features
• Horsepower Rated Sizes HA-HT
• Double Break Contacts
• Silver Tin Oxide Contacts,
Q- -mi
Cadmium-Free
"1 • Higher Locked Rotor Current Ratings,
I<5 1-8Ja
Up to 840% (Sizes HG-HT)
Arc Chutes with Arc Splitters;
aZ o«c Fast Arc Quenching
Touch Safe Power Terminals
(Sizes HA-HL)
Touch Safe Control Terminals
(Sizes HA-HT)
Snap-on 2 NO and 2 NC Auxiliary
Contacts Standard (Sizes HE-HT)
Visual ON-OFF Indicator
Color-Coded Coils
Fast Termination System—Wire
Funnels, Wire Stops, Screwdriver
Guide Holes, and Captive Hardware
Long Mechanical Life
—15 Million (Size HA-HD)
—10 Million (Size HE-HT)
UL Listed and CSA Certified
HP Rated Starters and Contactors Application Data
HP Rated Starter Size
HA HB HC HD HE HG HH HJ HL HN HR HT
Ampere Rating (Enclosed)
Max LRA in % of FLA
Maximum Voltage Rating
Amps 20 20 30 30 55 80 80 110 160 200 300 400
Percent 600 600 600 600 600 840 840 840 840 840 840 840
Volts 600 600 600 600 600 600 600 600 600 600 600 600
Ambient Temperature Range
In Operation
DegC -25 to +55 -25 to +55 -25 to +55 -25 to +55 -25 to +55 -25 to +55 -25 to +55 -25 to +55 -25 to +55 -25 to +55
When Stored
DegC -50 to +80 -50 to +80 -50 to +80 -50 to +80 -50 to +80 -50 to +80 -50 to +80 -50 to +80 -50 to +80 -50 to +80
200V, 60HZ HP
2
3
5
7/2 10
15 20 25 40
50
Squirrel Cage Motor
230V, 60HZ HP
3
3
5
T/2 10 20 25 30 50 60
Maximum 3 Phase
380V, 50HZ HP
5
5
10 15 20 30 40 50 75 125
HP at Motor
Voltages
460V, 60HZ HP
5
7'/z 10 15 25 40 50 60 100 125
575V, 60HZ HP
T/i
10
15
20
30
50
60
75
125 150
Overall HZ 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60
AC Coil Ratings
Inrush VA 77/71
PF 0.81/0.75
121/117 225/192
0.79/0.72 0.6/0.54
398/345
0.5/0.4
660/575
0.4
910/1090
0.38/0.31
Sealed VA 11/9
PF 0.28/0.27
16.5/13 24/16
0.27/0.28 0.29
46/29
56/36
58/70
0.23/0.24 0.24/0.25 0.26/0.28
AC Coil Voltage Range 85 to 110% Volts Yes
| Yes
| Yes
| Yes
Yes
Yes
Yes
Yes
Yes
Yes
Operating Times Valid for 20% Undervoltage to 10% Overvoltage, Warm or Cold Coil. (Total Opening Time Includes Arcing Time)
-25 to +55
-50 to +80
75
100
150
200
250
50/60
1430/1710
0.34/0.26
84/105
0.24/0.27
Yes
-25 to +55
-50 to +80
125
150
250
300
400
50/60
2450/2760
0.28/0.18
115/146
0.33
Yes
Closing Delay
MS 8-35
8-35
10-35
10-35
13-57
Opening Delay
MS 4-18 4-18 5-20 5-20
5-10
Resistance to Shock
(Rectangular Pulse]
g/MS 7.7/5 and 4.4/10 and 5.5/5 and 3.2/10 and 5.7/5; 9.5
4.4/10 7.7/5
3.2/10 5.5/10
Conductor Size/Phase
AWG (2)18-12 (2)18-12 (2)14-10 (2)14-10 Max #3
Auxiliary Contact (Double Bridge NEMA A600/P600 Rating — Suitable for Electronic Interface Circuits)
15-40 15-40
5-25 5-25
9.2/5 5.4/10
Max #1/0 Max #1/0
20-50
5-30
8.6/5
Max #1/0
20-50
8-30
9.4/5 and
5.2/10
Max #2/0
20-50
20-50
17-65
10-30
10-30
8-20
10.4/5 and 9.7/5 and 8.8/5 and
5.8/10
5.3/10
4.9/10
1/0-250KCM 2/0-500KCM 2/0-500KCM
Wire Size/Phase
Auxiliary Contacts-Standard
Auxiliary Contacts-Total
Contactor Mechanical Life
(Make/Break Operations)
Contactor UL Listing #
Contactor CSA Certification t
Starter UL Listing #
Starter CSACertification t
AWG
(2)18-12 (2)18-12 (2)18-12 (2)18-12 (2)18-12 (2)18-12 (2)18-12 |2| 18-12 (2)18-12 (2)18-12 (2)18-12 (2)18-12
1 NO, 1 NC 1 NO, 1 NC 1 NO, 1 NC 1 NO, 1 NC 2ND, 2NC 2 NO, 2 NC 2 NO, 2 NC Z N 0 . 2 N C 2 NO, 2 NC 2 NO, 2 NC 2ND, 2NC 2 NO, 2 NC
2 NO, 2 NC 2 N 0 . 2 N C 2ND, 2NC 2ND, 2NC 2 NO, 2 NC 4 NO, 4NC 4 NO, 4 NC 4 NO, 4NC 4 N 0 . 4 N C 4 NO, 4 NC 4 NO, 4NC 4 NO, 4 NC
Million 15 15 15 15 10 10 10 10 10 10 10 10
E31519
LR12730
E32529
LR38590
E31519
LR12730
E32529
LR38590
E31519
LR12730
E32529
LR38590
E31519
LR12730
E32529
LR38590
E31519
LR12730
E32529
LR38590
E31519
LR12730
E32529
LR38590
E31519
LR12730
E32529
LR38590
E31519
LR12730
E32529
LR38590
E31519
LR12730
E32529
LR38590
E31519
LR12730
E32529
LR38590
E31519
LR12730
E32529
LR38590
E31519
LR12730
E32529
LR38590
J9IL
Siemens Industrial Control Products










Скачать PDF:

[ 3UA6200-2X.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
3UA6200-2HOverload RelaysSiemens
Siemens
3UA6200-2WOverload RelaysSiemens
Siemens
3UA6200-2XOverload RelaysSiemens
Siemens

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск