DataSheet26.com

STR-K751P PDF даташит

Спецификация STR-K751P изготовлена ​​​​«Sony» и имеет функцию, называемую «FM STEREO FM-AM RECEIVER SERVICE MANUAL».

Детали детали

Номер произв STR-K751P
Описание FM STEREO FM-AM RECEIVER SERVICE MANUAL
Производители Sony
логотип Sony логотип 

30 Pages
scroll

No Preview Available !

STR-K751P Даташит, Описание, Даташиты
SERVICE MANUAL
Ver 1.0 2003. 04
STR-K751P
US Model
• STR-K751P is the tuner and the amplifier
section in HT-1800DP.
Dolby Laboratories Licensing Corporation.
“DOLBY” the double-D symbol ; “AC-3” and “PRO LOGIC”
are trademarks of Dolby Laboratories Licensing Corporation.
SPECIFICATIONS
POWER OUTPUT AND TOTAL
HARMONIC DISTORTION:
With 8 ohm loads, both channels driven, from
40 – 20,000 Hz; rated 90 watts per channel
minimum RMS power, with no more than
0.7 % total harmonic distortion from 250
milliwatts to rated output (Models of area code
U only).
Amplifier section
POWER OUTPUT
Rated Power Output at Stereo Mode
(8 ohms 40 Hz – 20 kHz, THD 0.7 %)
90 W + 90 W
Reference Power Output
(8 ohms 1 kHz, THD 0.7 %)
FRONT1):100 W/ch
CENTER1): 100 W
SURR1): 100 W/ch
1) Depending on the sound field settings and the
source, there may be no sound output.
Frequency response
CD, MD/TAPE, DVD,
VIDEO 1, 2
10 Hz – 50 kHz
+0.5/–2 dB (with sound
field and tone bypassed)
Inputs (Analog)
CD, MD/TAPE, DVD,
VIDEO 1, 2
Sensitivity: 500 mV
Impedance: 50 kilohms
S/N2): 96 dB
(A, 500 mV3))
2) INPUT SHORT (with sound field and tone
bypassed).
3) Weighted network, input level.
Inputs (Digital)
DVD (Coaxial)
VIDEO 2 (Optical)
Sensitivity: –
Impedance: 75 ohms
S/N: 100 dB
(A, 20 kHz LPF)
Sensitivity: –
Impedance: –
S/N: 100 dB
(A, 20 kHz LPF)
Outputs
MD/TAPE (OUT),
VIDEO 1
(AUDIO OUT)
SUB WOOFER
Voltage: 500 mV
Impedance: 10 kilohms
Voltage: 2 V
Impedance: 1 kilohms
Tone
Gain levels:
±6 dB, 1 dB step
— Continued on next page —
FM STEREO FM-AM RECEIVER
9-877-325-01
2003D167800-1
© 2003.04
Sony Corporation
Home Audio Company
Published by Sony Engineering Corporation
Free Datasheet http://www.Datasheet4U.com









No Preview Available !

STR-K751P Даташит, Описание, Даташиты
STR-K751P
FM tuner section
Tuning range
87.5 - 108.0 MHz
Antenna terminals 75 ohms, unbalanced
Intermediate Frequency
10.7 MHz
Sensitivity
Mono:
Stereo:
Usable sensitivity
S/N
Mono:
Stereo:
18.3 dBf, 2.2 µV/75 ohms
38.3 dBf, 22.5 µV/75 ohms
11.2 dBf, 1 µV/75 ohms
76 dB
70 dB
Harmonic distortion at 1 kHz
Mono:
0.3%
Stereo:
0.5%
Separation
45 dB at 1 kHz
Frequency response 30 Hz – 15 kHz,
+0.5/–2 dB
Selectivity
60 dB at 400 kHz
AM tuner section
Tuning range
With 10-kHz tuning scale: 530 – 1710 kHz4)
With 9-kHz tuning scale: 531 – 1710 kHz4)
Antenna
Loop antenna
Intermediate Frequency
450 kHz
Usable sensitivity
50 dB/m (at 1,000 kHz or
999 kHz)
S/N 54 dB (at 50 mV/m)
Harmonic distortion 0.5 % (50 mV/m, 400 Hz)
Selectivity
At 9 kHz:
At 10 kHz:
35 dB
40 dB
4) You can change the AM tuning scale to 9 kHz or
10 kHz. After tuning in any AM station, turn off
the receiver. Hold down PRESET TUNING + and
press ?/1. All preset stations will be erased when
you change the tuning scale. To reset the scale to
10 kHz (or 9 kHz), repeat the procedure.
Video section
Inputs
Video:
Outputs
Video:
1 Vp-p, 75 ohms
1 Vp-p, 75 ohms
General
Power requirements 120 V AC, 60 Hz
Power consumption 185 W
Power consumption (during standby mode)
0.3 W
Dimensions
430 × 145 × 298 mm
(16 7/8 × 5 6/8 × 11 6/8
inches) including
projecting parts and
controls
Mass (Approx.)
7.2 kg (15 lb 14 oz)
Design and specifications are subject to change without notice.
2
Free Datasheet http://www.Datasheet4U.com









No Preview Available !

STR-K751P Даташит, Описание, Даташиты
STR-K751P
SAFETY CHECK-OUT
After correcting the original service problem, perform the
following safety checks before releasing the set to the customer:
Check the antenna terminals, metal trim, “metallized” knobs, screws,
and all other exposed metal parts for AC leakage. Check leakage as
described below.
LEAKAGE
The AC leakage from any exposed metal part to earth ground
and from all exposed metal parts to any exposed metal part having
a return to chassis, must not exceed 0.5 mA (500 microamperes).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers’ instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The “limit” indication
is 0.75 V, so analog meters must have an accurate low-voltage
scale. The Simpson 250 and Sanwa SH-63Trd are examples of
a passive VOM that is suitable. Nearly all battery operated
digital multimeters that have a 2V AC range are suitable. (See
Fig. A)
To Exposed Metal
Parts on Set
Notes on chip component replacement
• Never reuse a disconnected chip component.
• Notice that the minus side of a tantalum capacitor may be
damaged by heat.
Unleaded solder
Boards requiring use of unleaded solder are printed with the lead-
free mark (LF) indicating the solder contains no lead.
(Caution: Some printed circuit boards may not come printed with
the lead free mark due to their particular size.)
: LEAD FREE MARK
Unleaded solder has the following characteristics.
• Unleaded solder melts at a temperature about 40°C higher than
ordinary solder.
Ordinary soldering irons can be used but the iron tip has to be
applied to the solder joint for a slightly longer time.
Soldering irons using a temperature regulator should be set to
about 350°C.
Caution: The printed pattern (copper foil) may peel away if the
heated tip is applied for too long, so be careful!
• Strong viscosity
Unleaded solder is more viscous (sticky, less prone to flow) than
ordinary solder so use caution not to let solder bridges occur such
as on IC pins, etc.
• Usable with ordinary solder
It is best to use only unleaded solder but unleaded solder may
also be added to ordinary solder.
0.15 µF
1.5 k
AC
Voltmeter
(0.75 V)
Earth Ground
Fig. A. Using an AC voltmeter to check AC leakage.
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK 0 OR DOTTED LINE WITH
MARK 0 ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS
LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE
COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS
APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS
PUBLISHED BY SONY.
3
Free Datasheet http://www.Datasheet4U.com










Скачать PDF:

[ STR-K751P.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
STR-K751PFM STEREO FM-AM RECEIVER SERVICE MANUALSony
Sony

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |