Micro-spectrometer
C12666MA
Finger-tip size, ultra-compact spectrometer head
integrating MEMS and image sensor technologies
The C12666MA is an ultra-compact (Finger-tip size) spectrometer head developed based on our MEMS and image sensor
technologies. The adoption of a newly designed optical system has achieved a remarkably small size, less than half the vol-
ume of the previous mini-spectrometer MS series (C10988MA-01). In addition, the employment of hermetic packaging has
improved humidity resistance.
This product is suitable for integration into a variety of devices, such as integration into printers and hand-held color
monitoring devices that require color management. It is also suitable for applications that collaborate with portable
devices, such as smartphones and tablets.
Features
Applications
Finger-tip size: 20.1 × 12.5 × 10.1 mm
Weight: 5 g
Spectral response range: 340 to 780 nm
Spectral resolution: 15 nm max.
Hermetic package: High reliability against humidity
Installation into mobile measurement equipment
Wavelength conversion factor*1 is listed on final inspection sheet
Color monitoring for printers and printing machines
Testers for lights and LEDs
Color adjustment of various large size displays
Water quality control monitors and other environment
measuring instruments
Measuring instruments that use portable devices
such as smartphones and tablets
*1: A conversion factor for converting the image sensor pixel number into a wavelength. A calculation factor for converting the A/D
converted count into the input light level is not provided.
Optical characteristics
Parameter
Value
Spectral response range
340 to 780
Spectral resolution (FWHM)
15 max.
Wavelength reproducibility*2
Wavelength temperature dependence
-0.5 to +0.5
-0.1 to +0.1
Spectral stray light*3
-25
*2: Measured under constant light input conditions
*3: Spectral stray light = 10 × log (Tl/Th)
Th: count measured when light at a certain wavelength is input
Tl: count measured at a wavelength 40 nm longer or shorter than the input light wavelength
Unit
nm
nm
nm
nm/°C
dB
Electrical characteristics
Parameter
Min.
Typ.
Max.
Unit
Supply voltage
4.75
5
5.25
V
Power consumption
- 30 - mW
Video rate
0.25
-
200 kHz
Output impedance
- 150 *4 - Ω
*4: An increase in the current consumption at the video output terminal also increases the chip temperature and so causes the dark
current to rise. To avoid this, connect a buffer amplier for impedance conversion to the video output terminal so that the current
ow is minimized. As the buffer amplier, use a JFET or CMOS input operational amplier of optical input impedance.
www.hamamatsu.com
1
http://www.Datasheet4U.com

1 page




C12666MA pdf
Micro-spectrometer
C12666MA
Dimensional outline (unit: mm, tolerance unless otherwise noted: ±0.2)
Slit
0.05 × 0.75
0.5
ϕ3.2
+0.1
-0
[Top view]
Index
mark
20.12
18.53
Slit position
[Side view]
[Bottom view]
0.47 ± 0.03
2.54 7.62
ϕ1.4 ± 0.05
Vdd
Video
GND
CLK
Case
NC
ST
NC
Gain
EOS
KACCA0336EB
Pin connections
Make electrical connections to an external circuit using leads.
Pin no.
1
Symbol
Vdd
Name
Supply voltage
I/O Description
I Image sensor power supply: 5 V
2 Video
Video output
O Video output signal
3 GND
4 CLK
Ground
Clock pulse
- Sensor ground
I Sensor scan sync signal
5 Case
Case
- Case connection terminal
6 NC
7 ST
Start pulse
- No connection
I Start pulse
8 NC
- No connection
9 Gain
10 EOS
Gain
End of scan
I Image sensor: Gain setting
O Sensor scan end signal
Note: Pin no. 9 is pulled up internally to Vdd via 10 kΩ.
Do not pull-up or pull-down the gain setting using an external circuit. For low gain, leave the pin open or connect to Vdd. For
high gain, connect to GND.
5
http://www.Datasheet4U.com

5 Page





C12666MA arduino
Micro-spectrometer
Related information
www.hamamatsu.com/sp/ssd/doc_en.html
Precautions
· Notice
Technical information
· Mini-spectrometer / Technical information
C12666MA
Information described in this material is current as of March, 2014.
Product specifications are subject to change without prior notice due to improvements or other reasons. This document has been carefully prepared and the
information contained is believed to be accurate. In rare cases, however, there may be inaccuracies such as text errors. Before using these products, always
contact us for the delivery specification sheet to check the latest specifications.
Type numbers of products listed in the delivery specification sheets or supplied as samples may have a suffix "(X)" which means preliminary specifications or
a suffix "(Z)" which means developmental specifications.
The product warranty is valid for one year after delivery and is limited to product repair or replacement for defects discovered and reported to us within that
one year period. However, even if within the warranty period we accept absolutely no liability for any loss caused by natural disasters or improper product
use.
Copying or reprinting the contents described in this material in whole or in part is prohibited without our prior permission.
www.hamamatsu.com
HAMAMATSU PHOTONICS K.K., Solid State Division
1126-1 Ichino-cho, Higashi-ku, Hamamatsu City, 435-8558 Japan, Telephone: (81) 53-434-3311, Fax: (81) 53-434-5184
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, P.O.Box 6910, Bridgewater, N.J. 08807-0910, U.S.A., Telephone: (1) 908-231-0960, Fax: (1) 908-231-1218
Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49) 8152-375-0, Fax: (49) 8152-265-8
France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: 33-(1) 69 53 71 00, Fax: 33-(1) 69 53 71 10
United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44) 1707-294888, Fax: (44) 1707-325777
North Europe: Hamamatsu Photonics Norden AB: Thorshamnsgatan 35 16440 Kista, Sweden, Telephone: (46) 8-509-031-00, Fax: (46) 8-509-031-01
Italy: Hamamatsu Photonics Italia S.R.L.: Strada della Moia, 1 int. 6, 20020 Arese, (Milano), Italy, Telephone: (39) 02-935-81-733, Fax: (39) 02-935-81-741
China: Hamamatsu Photonics (China) Co., Ltd.: 1201 Tower B, Jiaming Center, No.27 Dongsanhuan Beilu, Chaoyang District, Beijing 100020, China, Telephone: (86) 10-6586-6006, Fax: (86) 10-6586-2866
Cat. No. KACC1216E03 Mar. 2014 DN
11
http://www.Datasheet4U.com

11 Page







PáginasTotal 11 Páginas
PDF Descargar[ Datasheet C12666MA.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
C12666MAFinger-tip size ultra-compact spectrometer head integrating MEMSHAMAMATSU
HAMAMATSU

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar