3G3MX2 Даташит, Описание, Даташиты
3G3MX2
Designed With Machine Automation in Mind
• Current vector control
• High starting torque: 200% at 0.5Hz
• Double rating VT 120%/1min and CT 150%/1min
• Speed range up to 1000 Hz
• IM & PM motor control
• Torque control in open loop vector
• Positioning functionality
• Built-in application functionality (i.e. Brake control)
• User programmable as standard
• Safety embedded compliant with ISO13849-1 (double input
circuit and external device monitor EDM)
• USB port for PC programming
• 24 VDC backup supply for control board
• Fieldbus communications: Modbus, DeviceNet, Profibus,
Componet, Ethercat, ML-II and CanOpen
• PC configuration tool: CX-Drive
• RoHS, CE, cULus
Ratings
• 200 V Class single-phase 0.2 to 2.2 kW (1/8 to 3.0 HP)
• 200 V Class three-phase 0.2 to 15.0 kW (1/8 to 20 HP)
• 400 V Class three-phase 0.4 to 15.0 kW (1/2 to 20 HP)
System configuration
Power
Supply
MCCB
Input AC Reactor
Filter
USB Cable
Remote Operator
Extansion Cable
CX-Drive
CX-One
LCD 5 lines
Remote Operator
Communication Option Board
3G3MX2
Choke
Motor
Ground
Braking Resistor
DC Reactor
Output AC Reactor
8 Frequency inverters
Free Datasheet http://www.Datasheet4U.com









No Preview Available !

3G3MX2 Даташит, Описание, Даташиты
Specifications
Type designation
3G3MX2 A B 0 0 2 - E
3G3MX2 series
A: Standard specs
E: Europe standard
Voltage:
B: Single-phase 200 VAC
2: Three-phase 200 VAC
4: Three-phase 400 VAC
Max. applicable motor output
002: 0.2 kW (0.25HP)
150: 15.0 kW (20HP)
200 V class 3G3MX-A
Single-phase: MX2@
Three-phase: MX2@
Motor
kW2
For VT setting
For CT setting
200 VT
Inverter capacity kVA
200 CT
240 VT
240 CT
Rated output current (A) at VT
Rated output current (A) at CT
Max. output voltage
Max. output frequency
Rated input voltage
and frequency
Allowable voltage fluctuation
Allowable frequency fluctuation
Braking torque
At short-time
deceleration
At capacitor
feedback
Cooling method
AB001
A2001
0.2
0.1
0.4
0.2
0.4
0.3
1.2
1.0
AB002
A2002
0.4
0.2
0.6
0.5
0.7
0.6
1.9
1.6
AB004
A2004
0.55
0.4
1.2
1.0
1.4
1.2
3.5
3.0
100%: <50Hz
50%: <60Hz
Self cooling
AB0071 AB015 AB022
-
-
-
-
A2007 A2015 A2022 A2037 A2055 A2075 A2011
1.1 2.2 3.0 5.5 7.5 11 15
0.75
1.5
2.2
3.7 5.5
7.5
11
2.0
3.3
4.1
6.7
10.3
13.8
19.3
1.7
2.7
3.8
6.0
8.6
11.4
16.2
2.4
3.9
4.9
8.1
12.4
16.6
23.2
2.0
3.3
4.5
7.2
10.3
13.7
19.5
6.0
9.6
12.0
19.6
30.0
40.0
56.0
5.0
8.0
11.0
17.5
25.0
33.0
47.0
Proportional to input voltage: 0..240 V
1000 Hz3
Single-phase 200..240 V 50/60 Hz
3-phase 200..240 V 50/60 Hz
-15%..+10%
5%
70%:
<50Hz
50%:
<60Hz
Approx 20%
-
Forced-air-cooling
1. Single phase model use forced air cooling but three phase model is self cooling.
2. Based on a standard 3-Phase standard motor.
3. Above 400Hz with some function limitation.
-
A2150
18.5
15
23.9
20.7
28.6
24.9
69.0
60.0
400 V class 3G3MX-A4
Motor
kW1
Three-phase: MX2@
For VT setting
For CT setting
380 VT
Inverter capacity kVA
380 CT
480 VT
480 CT
Rated output current (A) at VT
Rated output current (A) at CT
Max. output voltage
Max. output frequency
Rated input voltage
and frequency
Allowable voltage
fluctuation
Allowable frequency
fluctuation
Braking torque
At short-time
deceleration *3
At capacitor
feedback
A4004
0.75
0.4
1.3
1.1
1.7
1.4
2.1
1.8
Cooling method
1. Based on a standard 3-Phase standard motor.
2. Above 400Hz with some function limitation.
A4007
1.5
0.75
2.6
2.2
3.4
2.8
4.1
3.4
A4015
2.2
1.5
3.5
3.1
4.4
3.9
5.4
4.8
100%: <50Hz
50%: <60Hz
A4022 A4030 A4040 A4055
3.0 4.0 5.5 7.5
2.2 3.0 4.0 5.5
4.5 5.7 7.3 11.5
3.6 4.7 6.0 9.7
5.7 7.3 9.2 14.5
4.5 5.9 7.6 12.3
6.9
8.8
11.1
17.5
5.5 7.2 9.2 14.8
Proportional to input voltage: 0..480 V
1000 Hz2
3-phase 380..480 V 50/60 Hz
-15%..+10%
5%
70%:
<50Hz
50%:
<60Hz
Forced-air-cooling
A4075
11
7.5
15.1
11.8
19.1
14.9
23.0
18.0
-
A4110
15
11
20.4
15.7
25.7
19.9
31.0
24.0
A4150
18.5
15
25.0
20.4
31.5
25.7
38.0
31.0
3G3MX2
9
Free Datasheet http://www.Datasheet4U.com









No Preview Available !

3G3MX2 Даташит, Описание, Даташиты
Specifications
Commom specifications
Model number
3G3MX@
Specifications
Control methods
Phase-to-phase sinusoidal pulse with modulation PWM (Sensorless vector control, close loop vector with motor feedback,
V/F)
Output frequency range
0.10..1000.00 Hz (with restrictions above 400Hz)
Frequency precision
Digital set value: ±0.01% of the max. frequency
Analogue set value: ±0.2% of the max. frequency (25 ±10 ºC)
Digital set value: 0.01 Hz
Resolution of frequency set value Analogue set value: 1/1000 of maximum frequency
Resolution of output frequency 0.01Hz
Starting torque
200% / 0.5Hz
Overload capability
Dual rating:
Heavy duty (CT): 150% for 1 minute
Normal Duty (VT): 120% for 1 minute
Frequency set value
0 to 10 VDC (10KΩ), 4 to 20mA (100Ω), RS485 Modbus, Network options
V/f Characteristics
Constant/ reduced torque, free V/f
Inputs signals
FW (forward run command), RV (reverse run command), CF1~CF4 (multi-stage speed setting), JG (jog command), DB (ex-
ternal braking), SET (set second motor), 2CH (2-stage accel./decel. command), FRS (free run stop command), EXT (external
trip), USP (startup function), CS (commercial power switchover), SFT (soft lock), AT (analog input selection), RS (reset), PTC
(thermistor thermal protection), STA (start), STP (stop), F/R (forward/reverse), PID (PID disable), PIDC (PID reset), UP (re-
mote control up function), DWN (remote control down function), UDC (remote control data clear), OPE (operator control),
SF1~SF7 (multi-stage speed setting; bit operation), OLR (overload restriction), TL (torque limit enable), TRQ1 (torque limit
changeover1), TRQ2 (torque limit changeover2), BOK (Braking confirmation), LAC (LAD cancellation), PCLR (position devi-
ation clear), ADD (add frequency enable), F-TM (force terminal mode), ATR (permission of torque command input), KHC (Cu-
mulative power clear), MI1~MI7 (general purpose inputs for EzSQ), AHD (analog command hold), CP1~CP3 (multistage-
position switches), ORL (limit signal of zero-return), ORC (trigger signal of zero-return), SPD (speed/position changeover),
GS1~GS2 (STO inputs, safety related signals), 485 (Starting communication signal), PRG (executing EzSQ program), HLD
(retain output frequency), ROK (permission of run command), EB (rotation direction detection of B-phase), DISP (display lim-
itation), OP (option control signal), NO (no function)
Output signals
RUN (run signal), FA1~FA5 (frequency arrival signal), OL,OL2 (overload advance notice signal), OD (PID deviation error sig-
nal), AL (alarm signal), OTQ (over/under torque threshold), UV (under-voltage), TRQ (torque limit signal), RNT (run time ex-
pired), ONT (power ON time expired), THM (thermal warning), BRK (brake release), BER (brake error), ZS (0Hz detection),
DSE (speed deviation excessive), POK (positioning completion), ODc (analog voltage input disconnection), OIDc (analog
current input disconnection), FBV (PID second stage output), NDc (network disconnect detection), LOG1~LOG3 (Logic out-
put signals), WAC (capacitor life warning), WAF (cooling fan warning), FR (starting contact), OHF (heat sink overheat warn-
ing), LOC (Low load), MO1~MO3 (general outputs for EzSQ), IRDY (inverter ready), FWR (forward operation), RVR (reverse
operation), MJA (major failure), WCO (window comparator O), WCOI (window comparator OI), FREF (frequency command
source), REF (run command source), SETM (second motor in operation), EDM (STO (safe torque off) performance monitor),
OP (option control signal), NO (no function)
Free-V/f, manual/automatic torque boost, output voltage gain adjustment, AVR function, reduced voltage start, motor data
selection, auto-tuning, motor stabilization control, reverse running protection, simple position control, simple torque control,
torque limiting, automatic carrier frequency reduction, energy saving operation, PID function, non-stop operation at
Standard functions
instantaneous power failure, brake control, DC injection braking, dynamic braking (BRD), frequency upper and lower
limiters, jump frequencies, curve accel and decel (S, U, inversed U,EL-S), 16-stage speed profile, fine adjustment of start
frequency, accel and decel stop, process jogging, frequency calculation, frequency addition, 2-stage accel/decel, stop mode
selection, start/end freq., analog input filter, window comparators, input terminal response time, output signal delay/hold
function, rotation direction restriction, stop key selection, software lock, safe stop function, scaling function, display
restriction, password function, user parameter, initialization, initial display selection, cooling fan control, warning, trip retry,
frequency pull-in restart, frequency matching, overload restriction, over current restriction, DC bus voltage AVR
Analogue inputs
2 analogue inputs 0 to 10V (10KΩ), 4 to 20mA (100Ω)
Pulse train input terminal
0 to 10V (up to 24V), up to 32KHz
Accel/Decel times
0.01 to 3600.0s (line/curve selection), 2nd accel/decel setting available
Display
Status indicator LED’s Run, Program, Alarm, Power, Hz, Amps
Digital operator: Available to monitor 32 items: frequency reference, output current, output frequency...
Motor overload protection
Electronic Thermal overload relay and PTC thermistor input
Instantaneous overcurrent
200% of rated current
Overload
Dual rating:
Heavy duty (CT): 150% for 1 minute
Normal Duty (VT): 120% for 1 minute
Overvoltage
800V for 400V type and 400V for 200V type
Undervoltage
345V for 400V type and 172.5V for 200V type
Momentary power loss
Following items are selectable: Alarm, decelerates to stop, decelerates to stop with DC bus controlled, restart
Cooling fin overheat
Temperature monitor and error detection
Stall prevention level
Stall prevention during acceleration/deceleration and constant speed
Ground fault
Detection at power-on
Power charge indication
On when power is supplied to the control part
Degree of protection
IP20, Varnish coating on PCB
Ambient humidity
90% RH or less (without condensation)
Storage temperature
-20 ºC..+65 ºC (short-term temperature during transportation)
Ambient temperature
10°C to 40°C
Installation
Indoor (no corrosive gas, dust, etc.)
Installation height
Vibration
Max. 1000 m
5.9 m/s2 (0.6G), 10 to 55 Hz
10
Frequency inverters
Free Datasheet http://www.Datasheet4U.com










Скачать PDF:

[ 3G3MX2.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
3G3MX2Current vector controlOmron
Omron

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск