DataSheet26.com

6EL1SC PDF даташит

Спецификация 6EL1SC изготовлена ​​​​«Tyco» и имеет функцию, называемую «Power Entry Module».

Детали детали

Номер произв 6EL1SC
Описание Power Entry Module
Производители Tyco
логотип Tyco логотип 

4 Pages
scroll

No Preview Available !

6EL1SC Даташит, Описание, Даташиты
L Series
CORCOM Product Guide
Power Entry Module with RFI Power Line Filter for General
or Medical Applications
UL Recognized
CSA Certified
VDE Approved
L Series
The L series power entry modules are compact units that
combine a multi-function power entry module and high per-
formance RFI filtering capabilities. They are available with
either a four-voltage selector or a DPST on/off switch. Both
variations can be specified with North American or
European fusing capabilities and are available in either
flange or snap-in mounting.
These filters are UL recognized, CSA certified, and VDE
approved. The L series modules offer a choice of filters for
general or medical applications.
EDL Models
The RFI filter is for general purpose applications where
line-to-line and line-to-ground noise must be controlled.
The filter is designed to meet the very low leakage
requirements of VDE portable equipment. They are
available in three current ratings.
EHL Models
This medical filter provides susceptibility protection
without the leakage current associated with line-to-ground
capacitors. Designed to allow equipment to meet UL544
for patient care and non-patient care equipment, the EHL
filter has a maximum leakage current of 2 µA at 120 VAC
60 Hz. See Appendix C for more information on medical
applications and UL standards.
Voltage Selection
EDL1S/EHL1S
EDL4C/EHL4C
To change selected voltage: disconnect the power cord;
open cover using a small blade screwdriver or similar tool;
insert the tool into the voltage selection slot and remove
wheel from unit; select desired voltage; replace wheel into
unit and close cover, making sure the selected voltage
appears in connector window.
Note: All models have North American or dual European fusing capability
and are available in either flange or snap-in mounting.
Voltage
selection
slot
4-Voltage
selection
wheel
Fuseholder
Cover
Note: When using the models with an IEC connector,
remember that the leakage current of the companion line
cord, GA400, is more significant than that of the filter -
which may disqualify this line cord from use in patient care
applications.
118
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
Free Datasheet http://www.datasheetlist.com/









No Preview Available !

6EL1SC Даташит, Описание, Даташиты
CORCOM Product Guide
L Series
Power Entry Module with RFI Power Line Filter for General
or Medical Applications (Continued)
Specifications
Electrical Schematics
DL Models (with switch)
Neutral
Ground
Hot
Note 1
Note 2
H On/Off
21
(1) (1a)
(2) (2a)
43
Cutomer
Transformer
Primaries
Device
G
DL Models (with 4-voltage selection)
Hot
Ground
Neutral
Note 1 G
120V
100V
Note 2 A
On/Off
B
C
D
E
F
H
220V
240V
Cutomer
Transformer
Primaries
AA
20V
BB
100V
CC
DD
E E 120V
FF
HL Models (with switch)
Neutral
Ground
Hot
Note 1
Note 2
H On/Off
21
(1) (1a)
(2) (2a)
43
G
Customer
Transformer
Primaries
Device
HL Models (with 4-voltage selection)
Hot
Ground
Neutral
Note 1 G
120V
100V
Note 2 A
On/Off
B
C
D
E
F
H
220V
240V
Customer
Transformer
Primaries
AA
20V
BB
100V
CC
DD
E E 120V
FF
Maximum leakage current, each line-to-ground:
@120 VAC 60 Hz:
@250 VAC 50 Hz:
EDL EHL
Models Models
0.25 mA 2 µA
0.50 mA 5 µA
Hipot rating (one minute):
line-to-ground
line-to-line
1500
1450
1500
1450
Operating frequency:
Operating voltages:
1S & 1SC Suffix (fixed):
4 & 4C Suffix (selectable):
Rated current:
50/60 Hz
250 VAC Max.
100, 120, 220, 240 VAC
2EDL & 2EHL
4EDL & 4EHL
6EL, 6EDL & 6EHL
2A
4A
6A
Switch:
Double-insulated, rated
for 10,000 operations at full
load. 51 Amp inrush capability.
Fuse (not included):
Accepts one .25" x 1.25" fuse
or two 5 x 20 mm fuses
Terminals:
110 [2.79] except for switch
.187 [4.8] for switch
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current
Frequency-MHz
Rating .05 .15 1
5
EDL Models
2A 6
4A 2
6A 1
EHL Models
06A 3
14 24 40
8 18 32
6 17 31
8 15 18
10
45
38
37
18
30
50
45
45
18
Line-to-line in 50 ohm circuit
Current
Rating .05
EDL Models
2A 7
4A 6
6A 6
EHL Models
06A 4
Frequency-MHz
.5 1 3
16 21 23
14 18 23
15 20 25
14 20 28
5
37
26
24
32
10 30
47 50
45 47
45 50
38 42
Note 1: Provision for dual European style fusing.
Note 2: On/Off switch present only with "S" suffix.
Resistor location for reference only.
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
119
www.corcom.com
www.tycoelectronics.com
Free Datasheet http://www.datasheetlist.com/









No Preview Available !

6EL1SC Даташит, Описание, Даташиты
L Series
CORCOM Product Guide
Flange mounted version
Power Entry Module with RFI Power Line Filter for General
or Medical Applications (Continued)
Case Styles — Unfiltered Models
Flange Models
Case Styles — Filtered Models
Flange Models
CD
34
12
GH
CD
F
B
A
34
12
GH
.221
5.61
.06
1.52
R
.020
.508
R
Side View
E
2.201*
55.91
2.213*
56.21
Back View
1.122*
28.50
1.575
40.00
* +.008 -.00
+.203 -.00
Recommended Panel Cutout
Typical dimensions:
Mounting Holes: .126 [3.20 ] Dia. (2)
All backplate terminals: .110 [2.79 ] terminals, except for switch.
Switch terminals are .187 [4.765 ] Note: Snap-in models allow front mounting only.
Snap-In Models
.221
5.61
Side View
E
Snap-SInnapM-in ovedrseionls
ACE
BD F
GH
CD
.221
5.61
Side View
E
Note: Metric fuse models have additional jumper from filter-to-module.
CD
F Side View
A
.221
5.61
E
.06
1.52
R
ACE
BD F
GH
.020
.508
R
(1)
2.201*
55.91
(2)
2.213*
56.21
Back View
1.122*
28.50
* +.008 -.00
+.203 -.00
Recommended Panel Cutout
(1) For panel thickness of .031-.079 [0.8-2.0]
(2) For panel thickness of .083-.126 [2.1-3.2]
(3) For snap-in application, the 1.22 [28.5] sides of the cutout must have a .02 [.508] radius on
the installation side.
All backplate terminals: .110 [2.79] terminals, except for switch. Switch terminals are .187 [4.75]
Note: Snap-in models allow front mounting only.
Case Dimensions
Part No.
Flange
Unfiltered
Snap-in
Unfiltered
Flange
Filtered
Snap-in
Filtered
ABC D E F
(max) ±.015 (max) (max) (max) (max)
±.381
1.98
50.29
1.28
32.51
1.575
40.0
2.3
58.42
2.3
58.42
2.14
54.36
2.14
54.36
1.66
42.16
1.66
42.16
1.11
28.19
1.11
28.19
1.98 1.575 2.3 2.14 2.01 1.11
50.29 40.0 58.42 54.36 51.05 28.19
1.28 2.3 2.14 2.01 1.11
32.51
58.42 54.36 51.05 28.19
120
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
Free Datasheet http://www.datasheetlist.com/










Скачать PDF:

[ 6EL1SC.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
6EL1SPower Entry ModuleTyco
Tyco
6EL1SCPower Entry ModuleTyco
Tyco
6EL1SCMPower Entry ModuleTyco
Tyco
6EL1SMPower Entry ModuleTyco
Tyco

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск