Спецификация 5EFM1SC изготовлена ​​​​«Tyco» и имеет функцию, называемую «Power Entry Module».

Детали детали

Номер произв 5EFM1SC
Описание Power Entry Module
Производители Tyco
логотип Tyco логотип 

8 Pages
scroll

No Preview Available !

5EFM1SC Даташит, Описание, Даташиты
M Series
CORCOM Product Guide
Power Entry Module with Optional RFI Power Line Filters for General and
Medical Applications
UL Recognized
CSA Certified
VDE Approved
XM/ZM
VM
M Series
The M series power entry modules offer the most choices
of power entry components and filtering options to fit a
specific need. The fully configured M series expands the
options of a manufacturer whose products are marketed
worldwide. One component, fully assembled and tested,
provides the capability of interfacing a multi-voltage power
supply to any common voltage or fusing scheme in the
world, without modification.
•The IEC connector provides an internationally accepted
power entry termination, which can be used with a variety
of line cords.
•The selectable fuseholder allows use of single or dual
European fuses, or a single North American fuse.
•The optional DPST on/off switch breaks both sides of the
line and is labeled with the international I/O markings.
•The optional voltage selector provides a convenient
means to change transformer primary connection,
and it is available in both 2-voltage and 4-voltage
configurations.
•The series is available with four filter circuits to meet a
variety of applications, and convenient connections are
provided on unfiltered models to allow wiring of a
separate RFI filter.
The M series is a family of components offering greater
flexibility and cost-effectiveness in the selection of primary
power components. Wiring to the modules is accom-
plished via .110” terminals for labor savings and
convenience.
FM Models – General purpose RFI filter designed for sus-
ceptibility applications, effectively providing RFI control of
line-to-ground noise. The design is compact and meets
the very low leakage current requirements of VDE portable
equipment as well as (120 Volt) UL544 non-patient medical
equipment.
XM Models – High performance RFI filter designed to bring
most digital equipment (including switching power
supplies) into compliance with FCC Part 15J, Class B
conducted emissions limits.
ZM Models – Premium RFI filter designed to bring most
digital equipment (including switching power supplies) into
compliance with EN55022, Level B (as well as FCC Part
15J, Class B) conducted emissions limits.
Fuse Installation Instructions
Four filter circuits provide a choice of attenuation tailored to
specific categories of susceptibility and emissions needs.
HM Models – This medical filter provides susceptibility
protection without the leakage current associated with
line-to-ground capacitors. Designed to allow equipment
to meet UL544 for patient care and non-patient care
equipment, the HM filter has a maximum leakage current
of 2 µA at 120 VAC 60 Hz. See Appendix C for more
information on medical applications and UL standards.
1. Remove power cord.
2. Pry door open at socket.
3. Lift and swing door into socket.
4. Lift fuse holder out of housing.
5. Install one (1) AG fuse or two (2) metric fuses*.
6. Replace fuse holder into housing.
7. Swing and snap door back in place.
*Install fuses on one side only, do not install both AG and metric fuses at the
same time.
124
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
Free Datasheet http://www.datasheet-pdf.com/









No Preview Available !

5EFM1SC Даташит, Описание, Даташиты
CORCOM Product Guide
M Series
Power Entry Module with Optional RFI Power Line Filters for General and
Medical Applications (Continued)
Fuse Options
European Fusing Arrangement**
Removing the Fuse Holder
1. Insert a pocket screwdriver at point “X” as shown.
"X"
A
North American Fusing Arrangement**
A Section A-A
Gently lift UP until the entire door lifts up approximately
1/4" (minimum).
Lift Up
**Install fuses on one side only. Do Not install both AG and Metric fuses at
the same time.
Voltage Selection
To change selected voltage: open cover, using small
blade screwdriver or similar tool; set aside cover/fuse
block assembly; pull voltage selector card straight out of
housing, using indicator pin; orient selector card so that
desired voltage is readable at the bottom; orient indicator
pin to point up when desired voltage is readable at bottom
(note that when indicator pin is fixed, successive voltages
are selected by rotating the card 90° clockwise); insert
voltage selector card into housing, printed side of card
facing forward toward IEC connector and edge containing
the desired voltage first; replace cover, and verify that
indicator pin shows the desired voltage.
Voltage Selector Card Orientation
2. Once lifted, the door will pivot on it’s hinges and
expose the fuse holder.
3. When the fuse holder is installed in the single fuse
position, apply the screwdriver as shown and gently
pry up. Use screwdriver as shown, do not use fingers.
When the fuse holder is installed in the dual fuse
position, it will normally release as soon as the
door is opened.
10 0
100V
12 0
120V
00
23 0
230V
24 0
240V
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
125
www.corcom.com
www.tycoelectronics.com
Free Datasheet http://www.datasheet-pdf.com/









No Preview Available !

5EFM1SC Даташит, Описание, Даташиты
CORCOM Product Guide
M Series
Power Entry Module with Optional RFI Power Line Filters for General and
Medical Applications (Continued)
Specifications
Maximum leakage current,each line-to-ground
HM FM
XM/ZM
@ 120 VAC 60 Hz:
@ 250 VAC 50 Hz:
Hipot rating (one minute):
2µA .25 mA .30 mA
5µA .50 mA .50 mA
line-to-ground:
1500 VAC
line-to-line
1450 VDC
line-to-load (switch off) Unfiltered only 2500 VAC
Operating frequency:
50/60 Hz
Rated voltage (max.):
250 VAC
Operating voltages:
100, 120, 220/ 240 VAC
Switch:
Double-insulated, rated for
100,000 operations at full load
at 70 Amps inrush current.
Fuse (not included):
Reversible fuseholder, accepts
one 1/4" x 1-1/4" fuse
or two 5 x 20 mm fuses
Terminals:
.110 [2.79] terminals
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current
Rating
HM
5A
FM
05A
XM
3A
ZM
3A
Frequency-MHz
.01 .05 .15 .5 1 5
- - 14 18 19 22
- - 14 21 26 40
2 13 23 40 46 44
15 29 39 46 43 40
10 30
22 17
45 40
44 44
40 40
Line-to-line in 50 ohm circuit
Current
Rating
XM
03A
ZM
3A
Frequency-MHz
.02 .03 .05 .07 .15 .5 1 5 10
- - - 5 34 62 68 60 50
5 13 28 37 55 75 75 62 54
30
40
44
Electrical Schematics – Unfiltered Models
VM (1-Voltage)
Neutral
Note 2
Power On/Off
Note 3
KK
Hot
120V
LL
G Customer
Transformer Primaries
VM (2-Voltage)
Neutral
Power On/Off
Note 3
Note 2
K
120V
Note 1
H
Hot
LJ
Note 1
240V
A
B
B
C
DD
EE
FF
G
120V
A
120V
C
120V
120V
F
Customer Note 4
Transformer Primaries
VM (4-Voltage)
Neutral
Power On/Off
Note 3
Note 2
K
120V
100V
Note 1
H
Hot
LJ
Note 1
230V
240V
A
B
A
20V
100V
CC
DD
EE
120V
FF
G Customer
Transformer Primaries
Note 1:
Note 2:
Note 3:
Note 4:
Jumpers required if no input filter is used.
Provision for dual European style fusing.
On/off switch present only with "S" suffix.
When using a center-tapped transformer, the C-F winding should
be the low voltage (high current) winding and must be capable of
handling the full primary current in the 120V position.
126
Catalog 1654001
Revised 05-07
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
Germany:
49-89-6089-0
www.corcom.com
www.tycoelectronics.com
Free Datasheet http://www.datasheet-pdf.com/










Скачать PDF:

[ 5EFM1SC.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
5EFM1SPower Entry ModuleTyco
Tyco
5EFM1SCPower Entry ModuleTyco
Tyco

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |