DataSheet26.com

AHK120X0 PDF даташит

Спецификация AHK120X0 изготовлена ​​​​«Panasonic» и имеет функцию, называемую «Relay».

Детали детали

Номер произв AHK120X0
Описание Relay
Производители Panasonic
логотип Panasonic логотип 

8 Pages
scroll

No Preview Available !

AHK120X0 Даташит, Описание, Даташиты
COMPACT AND
HIGH CAPACITY
GENERAL PURPOSE
POWER RELAYS
HK (AHK)
HK RELAYS (AHK)
RoHS Directive compatibility information
http://www.mew.co.jp/ac/e/environment/
FEATURES
1. Economical prices achieved
To assist rationalization, prices reduced
to about half the price of previous
products.
2. Compact with high-capacity
Enables high-capacity control:
15 A for 1 Form C, 10 A for 2 Form C
3. Types for wide range of applications
Range includes relays with operation
indicators, built-in diodes to absorb relay
coil surge, and built-in CR circuits.
4. Cadmium-free contacts
5. UL/C-UL and TÜV approved parts
available. Compliance with Japanese
Electrical Appliance and Material
Control Law is standard.
TYPICAL APPLICATIONS
Control panels
Power supply units
Molding machines
Machine tools
Welding equipment
Agricultural equipment
Office equipment
Vending machines
Communications equipment
Amusement machines, etc.
ORDERING INFORMATION
AHK
HK relays
Contact arrangement
1: 1 Form C
2: 2 Form C
Terminal arrangement
1: AC plug-in type
2: DC plug-in type
Type classification
0: Standard
1: With LED indication
2: With diode
3: With LED indication, diode
4: With CR circuit
5: With LED indication, CR circuit
Coil voltage
06: 6, 12: 12, 24: 24, 48: 48 V
X0: 100/110 V AC, 100/110 V DC
X1: 110/120 V AC
Y0: 200/220 V AC, Y2: 220/240 V AC
Note: Products conform to UL/C-UL and TÜV, as standard.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Free Datasheet http://www.datasheet-pdf.com/









No Preview Available !

AHK120X0 Даташит, Описание, Даташиты
HK (AHK)
TYPES
1. Plug-in type
Coil voltage
6V DC
12V DC
24V DC
48V DC
100/110V DC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
220/240V AC
1 Form C
Part No.
AHK12006
AHK12012
AHK12024
AHK12048
AHK120X0
AHK11012
AHK11024
AHK11048
AHK110X0
AHK110X1
AHK110Y0
AHK110Y2
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
2 Form C
Part No.
AHK22006
AHK22012
AHK22024
AHK22048
AHK220X0
AHK21012
AHK21024
AHK21048
AHK210X0
AHK210X1
AHK210Y0
AHK210Y2
2. Plug-in type (with LED indication)
Coil voltage
1 Form C
Part No.
6V DC
AHK12106
12V DC
AHK12112
24V DC
AHK12124
48V DC
AHK12148
100/110V DC
AHK121X0
12V AC
AHK11112
24V AC
AHK11124
48V AC
AHK11148
100/110V AC
AHK111X0
110/120V AC
AHK111X1
200/220V AC
AHK111Y0
220/240V AC
AHK111Y2
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
2 Form C
Part No.
AHK22106
AHK22112
AHK22124
AHK22148
AHK221X0
AHK21112
AHK21124
AHK21148
AHK211X0
AHK211X1
AHK211Y0
AHK211Y2
3. Plug-in type (with diode)
Coil voltage
1 Form C
Part No.
6V DC
AHK12206
12V DC
AHK12212
24V DC
AHK12224
48V DC
AHK12248
100/110V DC
AHK122X0
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
2 Form C
Part No.
AHK22206
AHK22212
AHK22224
AHK22248
AHK222X0
4. Plug-in type (with diode and LED indication)
Coil voltage
1 Form C
Part No.
2 Form C
Part No.
6V DC
AHK12306
AHK22306
12V DC
AHK12312
AHK22312
24V DC
AHK12324
AHK22324
48V DC
AHK12348
AHK22348
100/110V DC
AHK123X0
AHK223X0
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
5. Plug-in type (with CR)
Coil voltage
1 Form C
Part No.
100/110V AC
AHK114X0
110/120V AC
AHK114X1
200/220V AC
AHK114Y0
220/240V AC
AHK114Y2
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
2 Form C
Part No.
AHK214X0
AHK214X1
AHK214Y0
AHK214Y2
6. Plug-in type (with CR and LED indication)
Coil voltage
1 Form C
Part No.
100/110V AC
AHK115X0
110/120V AC
AHK115X1
200/220V AC
AHK115Y0
220/240V AC
AHK115Y2
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
2 Form C
Part No.
AHK215X0
AHK215X1
AHK215Y0
AHK215Y2
7. Accessories
Type
No. of poles
Item
Part No.
Terminal socket
1/2 poles (common)
HK screw terminal socket
HK screw terminal socket (Finger protect type)
AHKA21
AHKA21P
Standard packing: Carton: 10 pcs.; Case: 100 pcs.
Notes: 1. Use the retainer that is shipped with the terminal socket.
2. Products conform to UL, C-UL and TÜV, as standard.
3. In order to prevent breakage and disfiguring, the screw tightening torque for the terminal socket should be within the range of 0.784 to 0.98 N·m.
4. When attaching directly to a chassis, please use an M4 × 12 metric coarse screw thread, a spring washer, and a hexagonal nut.
Type
No. of poles
Plug-in socket
1-pole
2-pole
PC board socket
1-pole
2-pole
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Notes: 1. Use the retainer that is shipped with the terminal socket.
2. Products conform to UL/CSA as standard (TÜV is unacquired.)
Item
HL1 socket
HL2 socket
HL1 PC board socket
HL2 PC board socket
Part No.
HL1-SS-K
HL2-SS-K
HL1-PS-K
HL2-PS-K
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Free Datasheet http://www.datasheet-pdf.com/









No Preview Available !

AHK120X0 Даташит, Описание, Даташиты
HK (AHK)
RATING
1. Coil data
1) AC coils
Coil voltage
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
Nominal coil current, Nominal operating power,
mA V A
50Hz
60Hz
50Hz
60Hz
111
56
28
13.4/14.7
12.2/13.5
6.7/7.4
100
50
25
12/13.2
10.9/11.9
6/6.6
1.3
1.3
1.3
1.3
1.3
1.3
1.2
1.2
1.2
1.2
1.2
1.2
Pick-up voltage
(at 20°C 68°F)
80%V or less of
nominal voltage
(Initial)
Drop-out voltage
(at 20°C 68°F)
30%V or more of
nominal voltage
(Initial)
Inductance, H
When
drop-out
0.312
1.243
4.974
23.75
27.19
85.98
When
operating
0.295
1.181
4.145
20.63
25.57
81.76
Max. allowable
voltage
110%V of
nominal voltage
Notes: 1. The relay operates in a range of 80% to 110 % V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage. In particular, for AC operation, if the impressed voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will
flow leading possibly to coil burnout.
2. The maximum allowable voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
2) DC coils (at 20°C 68°F)
Coil voltage
Nominal coil current,
mA
Nominal operating
power, W
Coil resistance,
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Max. allowable voltage
(at 70°C 158°F)
6V DC
150
0.9
40
12V DC
24V DC
48V DC
75
37
18.5
0.9
0.9
0.9
160
650
2,600
80%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
100/110V DC
10
1.0 10,000
Notes) 1. The rated excitation current is ±10% (20°C 68°F).
2. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate ±0.4% for every ±1°C change in temperature.
3. The relay operates in a range of 80% to 110 % V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage.
4. For use with 200 V DC, connect a 10 K(5W) resistor, in series, to the 100 V DC relay.
5. The maximum allowable voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
2. Specifications
Characteristics
Contact
Rating
Electrical
characteristics
Mechanical
characteristics
Expected life
Item
Initial contact resistance, max
Contact material
Nominal switching capacity
Max. switching voltage
Max. switching current
Min. switching capacity (Reference value)*1
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Between open contacts
Between contact sets
Between contact and coil
Temperature rise
Operate time (at 20°C 68°F)*2
Release time (at 20°C 68°F)*2
Shock resistance
Vibration resistance
Mechanical
Functional
Destructive
Functional
Destructive
Electrical
AC load
Conditions
Unit weight
Conditions for operation, transport and storage*3
Max. Operating speed
Specifications
Max. 50 m(By voltage drop 6 V DC 1A)
AgSnO2 type
1 Form C: 15A 125V AC 2 Form C: 10A 125V AC
250V AC, 125V DC
15A (1 Form C), 10A (2 Form C)
100mA 5V DC
Min. 100M(at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA.)
2,000 Vrms for 1min. (Detection current: 10mA.)
2,000 Vrms for 1min. (Detection current: 10mA.)
Max. 80°C (By resistive method, nominal voltage)
Max. 25ms (Nominal voltage applied to the coil, excluding contact bounce time.)
Max. 25ms (Nominal voltage applied to the coil, excluding contact bounce time.)
(without diode)
Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 2 mm
AC type: 5×107 (at 180 cpm), DC type: 108 (at 180 cpm)
1 Form C: 15A 125V AC (cosϕ=1), Min. 2×105
2 Form C: 10A 125V AC (cosϕ=1), Min. 5×105
Ambient temperature:
–50°C to +70°C –58°F to +158°F (Without LED indication);
–50°C to +60°C –58°F to +140°F (With LED indication)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm (at max. rating)
Approx. 35g 1.23 oz
Notes: If integrating into electrical appliances that will be subject to compliance to the Electrical Appliance and Material Safety Law, please use in an ambient temperature
between –50°C to +40°C –58°F to +104°F (AC type).
*1 This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2 For the AC coil types, the operate/release time will differ depending on the phase.
*3 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value.Refer to 4. Conditions for operation,
transport and storage mentioned in AMBIENT ENVIRONMENT.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Free Datasheet http://www.datasheet-pdf.com/










Скачать PDF:

[ AHK120X0.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
AHK120X0RelayPanasonic
Panasonic

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск