DX1000 Series
Digital Video Recorder
Installation/
Operation Manual
C680M-G (7/01)
Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA • www.pelco.com
In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150
International Customers: Tel +1(559) 292-1981 • FAX +1(559) 348-1120
Free Datasheet http://www.datasheet4u.com/

1 page




DX1000 pdf
WARNING: Adequate
ventilation is required for
proper operation of the
DVR. Allow two inches of
space above the unit and on
each side for air circulation.
1 Connect cameras to the CAMERA INPUT connectors (BNC) on the rear of the DVR.
Refer to Table A for video coaxial cable distances.
2 Connect a monitor to the MONITOR OUTPUT connector (BNC) on the rear of the DVR.
Refer to Table A for video coaxial cable distances.
3 To save data from the DVR, connect a peripheral recording device to the VIDEO
PRINTER OUTPUT connector (BNC) on the rear of the DVR. Refer to Table A for
video coaxial cable distances.
Table A. Video Coaxial Cable Requirements
Cable Type*
Maximum Distance
RG59/U
RG6/U
RG11/U
750 ft (229 m)
1,000 ft (305 m)
1,500 ft (457 m)
* Minimum cable requirements:
75 ohms impedance
All-copper center conductor
All-copper braided shield with 95% braid coverage
4 Connect alarm inputs and alarm relay output as follows:
a. Inputs – Connect wiring (not supplied) to your alarms (not supplied). Two wires
are required for each alarm. You can have one alarm for each camera.
b. Output – Connect wiring (not supplied) to a 12 VDC light or buzzer (not supplied).
Two wires are required.
c. Bring the alarm input and output wiring to the back of the DVR and thread the
wiring through the Induced Voltage Protector (supplied). Loop the wiring over the
voltage protector and thread it through the voltage protector a second time.
d. Connect the alarm input wires to the SENSOR connectors.
e. Connect the light or buzzer to the ALARM output connectors.
5 Connect the recorder to power.
a. Place the NTSC/PAL switch in the proper mode.
b. If applicable, connect the 230 VAC adapter to the end of the power cord. Plug in
the power cord.
c. Turn on the DVR. When the recorder is turned on for the first time, the Help
screens will appear on the monitor. To bypass the Help screens, press the Play/
Pause button.
6 Turn on the cameras and monitor. The DVR begins recording the cameras.
IMPORTANT– If you have any unused camera inputs, the video appears washed out.
The degree of washout depends on how many inputs have no cameras connected to
them. If only one camera is connected, the video is completely washed out. When you
program the DVR (step 9), you must turn off any unused camera inputs. Video
will then appear normal.
7 Go to Time Menu in the Programming section and set the time and date.
8 Initialize the DVR. Refer to the instructions on a separate sheet.
This is a necessary step as the DVR may not operate properly during playback and
search operation if there are conflicts in the date and time. Initializing the DVR erases
all data on the hard disk drive so that you start with a clean file management system
for your recordings.
9 Proceed to the Programming section to set up the recording parameters and enter a
password (optional).
Pelco Manual C680M-G (7/01)
5
Free Datasheet http://www.datasheet4u.com/

5 Page





DX1000 arduino
ALARM OUTPUT MENU
NOTE: The alarm output
programming does not
affect recording. It only
affects the operation of the
alarm output relay. For
event (alarm) recording,
refer to Recording in the
Operation section.
The ALARM output on the rear panel is a single-pole, normally open, latching, dry contact.
This output can be used to notify you if there has been an alarm event that might require
review. The alarm output can be enabled or disabled (armed/disarmed) manually, or it can
be programmed to enable (arm) or disable (disarm) at the same time automatically every
day.
If the output is enabled and an alarm input is activated, the output relay will latch closed af-
ter a 20-second delay and will remain closed until it is manually disabled. The 20-second
delay allows you to enter your premises and disable the alarm output before it is activated.
The alarm output menu is used to set up automatic arming and disarming of the relay at
specified times each day. (For manual operation, refer to Alarm Relay Output Operation in
the Operation section.) This feature may be used in conjunction with the event recording
capabilities of the DX1000 to notify you that an alarm event was recorded.
Application example:
A company has a rear door that is not to be opened for any reason between 5 p.m. and 7
a.m. During the day, the area around this door is recorded continuously, but to conserve
disk space, the area is only recorded at night if the door is opened. The owner does not
want to review the video unless the door was opened after hours.
In this case, the alarm output would be programmed to enable at 5 p.m. and disable at 7 a.m.
The DX1000 would also be programmed for automatic (continuous) recording from 7 a.m. to
5 p.m. and event recording from 5 p.m. to 7 a.m. (refer to Camera Menu in the Programming
section).
At 5 p.m. continuous recording would cease. If an alarm input is activated, the DVR would
immediately begin recording the associated camera. The relay would latch closed after the
20-second delay. When the owner returned in the morning, a light attached to the relay
output would be on, indicating that there was an alarm during the night. A search for re-
corded video starting at 5 p.m. would immediately take you to the first alarm event. All
other events could be reviewed in sequence.
To program the relay for automatic arming/disarming:
Skip steps 1 and 2 if you are already in the Setup Menu.
1. Press and hold the Function button. The Function Key List appears. Keep holding the
Function button.
FUNCTION KEY LIST
0 : Setup
1 : Camera 1 recording/stop
2 : Camera 2 recording/stop
3 : Camera 3 recording/stop
4 : Camera 4 recording/stop
5 : All the cameras recording
6 : All the cameras stop
: Alarm On
: Alarm Off
2. Press and release the 0 button, and then release the Function button. Enter the pass-
word if requested. The Setup Menu appears.
SETUP MENU
Camera
All Resolution
Alarm Output
Time
Password
Exit
Help: ON
Pelco Manual C680M-G (7/01)
11
Free Datasheet http://www.datasheet4u.com/

11 Page







PáginasTotal 24 Páginas
PDF Descargar[ Datasheet DX1000.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
DX1000Digital Video Recorder Operation ManualPelco
Pelco

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar