Features
50.12
PCB Relay with forcibly guided contacts
according to EN 50205 type B
2 CO contacts *
High physical separation between adjacent
contacts
Cadmium Free contact materials
8 mm, 6 kV (1.2/50 µs) isolation, coil-contacts
Flux proof: RT II
2 Pole 8 A
5 mm pinning
PCB mounting
29 12.4
A1 12 11 14
A2 22 21 24
0.4 1
55
*According to EN 50205 only 1 NO and 1 NC
(11-14 and 21-22 or 11-12 and 21-24) shall be
used as forcibly guided contacts.
2.5 20 6
29
FOR UL HORSEPOWER AND PILOT DUTY RATINGS
SEE “General technical information” page V
Copper side view
Contact specification
Contact configuration
2 CO (DPDT)
Rated current/Maximum peak current
A
8/15
Rated voltage/Maximum switching voltage V AC
250/400
Rated load AC1
VA 2,000
Rated load AC15 (230 V AC)
VA
500
Single phase motor rating (230 V AC) kW
0.37
Breaking capacity DC1: 30/110/220 V A
8/0.65/0.2
Minimum switching load
mW (V/mA)
300 (5/5)
Standard contact material
AgNi
Coil specification
Nominal voltage (UN)
V AC (50/60 Hz)
V DC 5 - 6 - 12 - 24 - 48 - 60 - 110 - 125
Rated power AC/DC
VA (50 Hz)/W
—/0.7
Operating range
AC (50 Hz)
Holding voltage
Must drop-out voltage
Technical data
DC
AC/DC
AC/DC
(0.75…1.2)UN
—/0.4 UN
—/0.1 UN
Mechanical life AC/DC
cycles
—/10 · 106
Electrical life at rated load AC1
cycles
100 · 103
Operate/release time
ms 10/4
Insulation between coil and contacts (1.2/50 µs) kV
6 (8 mm)
Dielectric strength between open contacts V AC
1,500
Ambient temperature range
°C –40…+70
Environmental protection
RT II
Approvals (according to type)
50 Series - Safety relay 8 A
1









No Preview Available !

50.12.xxxxx Даташит, Описание, Даташиты
www.DataSheet4U.com
50 Series - Safety relay 8 A
Ordering information
Example: 50 series safety relay, 2 CO (DPDT) 8 A contacts, 24 V DC coil.
ABCD
5 0.1 2.9.0 2 4.1 0 0 0
Series
Type
1 = PCB - 5 mm pinning
No. of poles
2 = 2 pole 8 A
Coil version
9 = DC
Coil voltage
See coil specifications
A: Contact material
1 = Standard AgNi
4 = AgSnO2
5 = AgNi + Au (5 µm)
B: Contact circuit
0 = CO (DPDT)
D: Special versions
0 = Flux proof (RT II)
C: Options
0 = None
Selecting features and options: only combinations in the same row are possible.
Preferred selections for best avaliability are shown in bold.
Type Coil version A
BC D
50.12
DC
1-4-5
0
0
0
Technical data
Insulation according to EN 61810-1:2004
Nominal voltage of supply system
V AC
Rated insulation voltage
V AC
Pollution degree
Insulation between coil and contact set
Type of insulation
Overvoltage category
Rated impulse voltage
kV (1.2/50 µs)
Dielectric strength
V AC
Insulation between adjacent contacts
Type of insulation
Overvoltage category
Rated impulse voltage
kV (1.2/50 µs)
Dielectric strength
V AC
Insulation between open contacts
Type of disconnection
Dielectric strength
V AC/kV (1.2/50 µs)
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2
Surge (1.2/50 µs) on A1 - A2 (differential mode)
Other data
Bounce time: NO/NC
ms
Vibration resistance (5…55)Hz: NO/NC
g
Shock resistance NO/NC
g
Power lost to the environment
without contact current
W
with rated current
W
Recommended distance between relays mounted on PCB
mm
230/400
250
3
Reinforced (8 mm)
III
6
4,000
Basic
III
4
2,500
Micro-disconnection
1,500/2.5
EN 61000-4-4
EN 61000-4-5
2/10
20/2
20/5
0.7
1.2
5
400
2
level 4 (4 kV)
level 3 (2 kV)
2









No Preview Available !

50.12.xxxxx Даташит, Описание, Даташиты
www.DataSheet4U.com
Contact specification
F 50 - Electrical life (AC) v contact current
107
Resistive load - cosϕ = 1
Inductive load - cosϕ = 0.4
106
105
0
2
46
12 14 22 24 12 14 22 24
50 Series - Safety relay 8 A
H 50 - Maximum DC1 breaking capacity
20
10
6
4
2
1
0.2
0.1
8 20 60 100 140 180 220
(A) DC voltage (V)
When switching a resistive load (DC1) having voltage and current
values under the curve, an electrical life of 100·103 can be expected.
In the case of DC13 loads, the connection of a diode in parallel with
the load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
11 21
11 21
A1 A2 A1 A2
Alternative selection of NO and NC
contacts to provide Forcibly guided
(mechanically linked) contacts, in
accordance with EN 50205 (type B).
Coil specifications
DC coil data
Nominal
voltage
UN
V
5
6
12
24
48
60
110
125
Coil
code
9.005
9.006
9.012
9.024
9.048
9.060
9.110
9.125
Operating range
Umin
V
3.8
4.5
9.0
18
36
45
82.5
93.7
Umax
V
6.0
7.2
14.4
28.8
57.6
72.0
131.0
150
Resistance Rated coil
consumption
R I at UN
mA
35 143
50 120
205 58.5
820 29.3
3,280
14.4
5,140
11.7
17,250
6.4
22,300
5.6
R 50 - DC coil operating range v ambient temperature
Standard coil
U 2.0
UN
1
1.5
1.0
0.5
-20
0
2
20 40 60 80
(°C)
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
3










Скачать PDF:

[ 50.12.xxxxx.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
50.12.xxxxxSakety RelayFinder
Finder

Номер в каталоге Описание Производители
TL431