Current Transducer HX 02..06-P
IPN = 2 .. 6 A
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
Primary nominal Primary current
r.m.s. current measuring range
I
PN
(A)
I
P
(A)
2 ±6
3 ±9
4 ±12
6 ±18
Primary Conductor
Diameter x Turns
(mm)
0.5d x 30T
0.6d x 20T
0.7d x 15T
1.0d x 10T
Type
HX 02-P
HX 03-P
HX 04-P
HX 06-P
V
OUT
ROUT
R
L
VC
I
C
Vd
V
e
www.DataSheet4U.com
Output
voltage
@
±
I,
PN
R
L
=
10
k,
T
A
=
25°C
Output impedance
Load resistance
Supply voltage (± 5 %)1)
Current consumption
R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn
R.m.s. voltage for partial discharge extinction
at 10pC
Impulse withstand voltage, 1.2/50µs
±4
< 50
10
± 15
< ± 15
>3
1
6
V
k
V
mA
kV
kV
kV
Accuracy-Dynamic performance data
X
εL
VOE
VOH
εVOT
TC G
tr
f
Accuracy @ IPN, TA = 25°C (without offset)
Linearity error (0 .. ± IPN)
Electrical offset voltage, TA = 25°C
Hysteresis offset voltage @ IP = 0;
after an excursion of 3 x IPN
Thermal drift of VOE
Thermal drift of the gain (% of reading)
Response time @ 90% of IP
Frequency bandwidth (-3 dB) 2)
< ± 1 % of IPN
< ± 1 % of IPN
< ± 40
mV
< ± 15
max. ± 1.5
± 0.1
3
50
mV
mV/K
%/K
µs
kHz
General data
TA Ambient operating temperature
TS Ambient storage temperature
m Mass
Min. internal creepage distance/clearance
Isolation material group
Standards
- 25 .. + 85 °C
- 25 .. + 85 °C
8g
5.5
mm
I
EN50178
Features
Galvanic isolation between primary
and secondary circuit
Hall effect measuring principle
Isolation voltage 3000V
Low power consumption
Extended measuring range 3x IPN
Power supply from ±12V to ±15V
Material according to UL94-V0
Advantages
Low insertion losses
Easy to mount with automatic
handling system
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
Applications
Switched Mode Power Supplies
(SMPS)
AC variable speed drives
Uninterruptible Power Supplies
(UPS)
Electrical appliances
Battery supplied applications
DC motor drives
Application Domain
Industrial
Notes : 1) Also operate at ±12V power supplies, measuring range reduced to ±2.5x IPN
2) Small signal only to avoid excessive heating of the magnetic cores
060920/1
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/2
www.lem.com









No Preview Available !

HX03-P Даташит, Описание, Даташиты
Dimensions HX 02..06-P (in mm. 1 mm = 0.0394 inch)
HXHHXX00023.2..0..62.-25P-5P-P
19 Max.
HXHX5500-PP
Terminal Pin Identification
19 Max.
1 ..... -15 V
2 ..... 0 V
3 ..... +15 V
4 ..... Output
5 ..... Primary input Current (+)
6 ..... Primary input Current (-)
3 10.85
d
4 OUT
3 +V
20
1 -V or 0
6
5
3 10.85
Terminal Pin Identification
1.....-15V
2.....0V
3.....+15V
4.....Output
5.....Primary input Current(+)
6.....Primary input Current(-)
Primary conductor diameter
3 8.8
5.4
HX 02-P
03-P
04-P
d 0.56 0.6 0.7
06-P
1.0
4 OUT
65
3S+eVcondary pins dimension
20.05 x 0.25
1 -V or 0
1.2
3 8.8
5.4
Top view
HHXX 0025--PP
41123
Lot No.
Primary conductor diameter / dimension
Safety
HX 03-P 05-P 10-P 15-P 20-P 25-P 50-P
d 0.6 0.8 1.1 1.4 1.6 1.6 1.2x6.3
SecondarTyhpisinstradinmsednuscioenr must be used in electric/electronic equipment
0.5x0w.2i5th respect to applicable standards and safety requirements
in accordance with the following manufacturer's operating
instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can
carry hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious
damage.
This transducer is a built-in device, whose conducting parts
must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
060920/1
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 2/2
www.lem.com










Скачать PDF:

[ HX03-P.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
HX03-PCurrent Transducer HX 03~50-PLEM
LEM
HX03-P(HX02-P - HX06-P) Current TransducerLEM
LEM

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск