DataSheet39.com

What is LF420?

This electronic component, produced by the manufacturer "Toshiba", performs the same function as "(LF400 - LF490) Sanitary Electromagnetic Flowmeter".


LF420 Datasheet PDF - Toshiba

Part Number LF420
Description (LF400 - LF490) Sanitary Electromagnetic Flowmeter
Manufacturers Toshiba 
Logo Toshiba Logo 


There is a preview and LF420 download ( pdf file ) link at the bottom of this page.





Total 10 Pages



Preview 1 page

No Preview Available ! LF420 datasheet, circuit

Field Intelligent Device Series
Sanitary Electromagnetic Flowmeter
LF490 / LF400
LF490 / LF420
25 to 100mm(1S to 4S)
Introduction
Sanitary electromagnetic flowmeter LF490/LF400 or
LF490/LF420 is designed for applications handling
food and beverages. Sanitary flowmeters must be
structured in such a way that operation and handling is
simple, easy and thorough for the purpose of sanitary
control such as cleaning, sterilization and drying. The
sanitary flowmeter has features provided with normal
electromagnetic flowmeters and by using sanitary
fittings for pipeline connections fluid does not remain
in any place along the detector pipeline. Thus, it is fit
for flowrate measurement for food and beverages.
The electromagnetic flowmeter uses Faraday’s Law of
electromagnetic induction to measure the process flow.
The device consists of two units: a detector, through
which the fluid to be measured flows and in which low-
level signals proportional to flow rates are obtained;
and a converter, which supplies excitation current to
the detector, and amplifies the signals from the detector
and then processes and converts the signals into the
4–20 mA dc current signal. The LF490/LF400 is a
detector-converter combined type and the LF490/LF420
is a flowmeter with its detector LF490 and converter
LF420 separately mounted. The LF490 detector can
also be used with a separate type converter Model
LF230, which provides high performance such as
Digital Inputs (two points) along with Digital Outputs
(four points), and multi-functions.
The LF490 is approved for 3A standard and its teflon
PFA lining conforms FDA requirement.
The AF100 hand-held terminal or Model 275 HART
communicator can be used to communicate with the
flowmeter from remote places. See the following page
for the HART protocol specifications.
Figure 2. Separate type LF490 and LF420
Specifications
Overall Specifications
Measurement range in terms of flow velocity:
0 – 0.3 m/s to 0 –10 m/s (0 –1.0 ft/s to 0 – 32.8 ft/s).
0 – 0.1 m/s to 0 – 0.3 m/s (0 – 0.3 ft/s to 0 – 1.0 ft/s)
range is available optionally.
Accuracy: See the following table.
Flow rate as a
Accuracy
percent of 0.1– 0.3 m/s 0.3–1.0 m/s 1.0–10 m/s
range
(0.3–1.0 ft/s) (1.0–3.3 ft/s) (3.3–32.8 ft/s)
0 – 20%
— ±0.1% FS
20 – 100%
— ±0.5% of rate
0 – 50%
±0.25% FS
50 – 100%
±0.5% of rate
Note: The accuracy above is measured under standard
operating conditions at Toshiba's calibration facility.
Power supply
Converter
Converter Fluid conductivity: 5µS/cm minimum
Fluid temperature: –10 to +120 °C (14 to 248 °F)
Ambient temperature: –10 to +60 °C (14 to 140 °F)
Excitation cable
Structure: NEMA 4 (IP 67) Watertight
Power supply Power consumption: approximately 10 W(17VA)
I/O
Signal cable I/O
Model LF490 Detector
Detector
Combined type
flowmeter
LF490 / LF400
Detector
Separate type
flowmeter
LF490 / LF420
Figure1. Configuration
Fluid pressure: –0.1 to 2.0 MPa (–15 to 300 psi,
or –1.0 to 20 bar)
Note: This pressure is the allowable pressure for
the detector. The actual pressure will be restricted
by the type of connection method. For example,
in the case of sanitary clamp type, the maximum
pressure is 1.0 MPa (150 psi or 10 bar).
www.DataSheet4U.com
www.DataSheet4U.com
EJL- 088A

line_dark_gray
LF420 equivalent
8QLW=##PP
150
74
4 -11 DIA.
holes
117
13
LCD
Port for excitation cable PortforI/Ocable
Grounding terminal
Portforpowercable
Portforsignalcable
Weight: approx. 3.5 kg (7.7 lb)
(including a mounting bracket)
Blindscrew
Figure 8. Separate type converter LF420
8QLW=##PP
150 4 -11 DIA. holes 117
74 13
LF490/LF400, LF490/LF420
Terminal box
Portforpowercable PortforI/Ocable
Grounding terminal
Portforexcitationcable
Reserved port
Port for signal cable
Weight: approx. 5 kg (11 lb)
(including a mounting bracket)
Figure 9. Separate type converter LF420
Note: 1 inch = 25.4 mm
5


line_dark_gray

Preview 5 Page


Part Details

On this page, you can learn information such as the schematic, equivalent, pinout, replacement, circuit, and manual for LF420 electronic component.


Information Total 10 Pages
Link URL [ Copy URL to Clipboard ]
Download [ LF420.PDF Datasheet ]

Share Link :

Electronic Components Distributor


An electronic components distributor is a company that sources, stocks, and sells electronic components to manufacturers, engineers, and hobbyists.


SparkFun Electronics Allied Electronics DigiKey Electronics Arrow Electronics
Mouser Electronics Adafruit Newark Chip One Stop


Featured Datasheets

Part NumberDescriptionMFRS
LF420The function is (LF400 - LF490) Sanitary Electromagnetic Flowmeter. ToshibaToshiba

Semiconductors commonly used in industry:

1N4148   |   BAW56   |   1N5400   |   NE555   |  

LM324   |   BC327   |   IRF840  |   2N3904   |  



Quick jump to:

LF42     1N4     2N2     2SA     2SC     74H     BC     HCF     IRF     KA    

LA     LM     MC     NE     ST     STK     TDA     TL     UA    



Privacy Policy   |    Contact Us     |    New    |    Search