DataSheet26.com

X40011S8I-B PDF даташит

Спецификация X40011S8I-B изготовлена ​​​​«Xicor» и имеет функцию, называемую «Dual Voltage Monitor with Integrated CPU Supervisor».

Детали детали

Номер произв X40011S8I-B
Описание Dual Voltage Monitor with Integrated CPU Supervisor
Производители Xicor
логотип Xicor логотип 

25 Pages
scroll

No Preview Available !

X40011S8I-B Даташит, Описание, Даташиты
New Features
• Monitor Voltages: 5V to 0.9V
• Independent Core Voltage Monitor
Preliminary Datasheet
X40010/X40011/X40014/X40015
Dual Voltage Monitor with Integrated CPU Supervisor
FEATURES
• Dual voltage detection and reset assertion
—Standard reset threshold settings
See Selection table on page 2.
—Adjust low voltage reset threshold voltages
using special programming sequence
—Reset signal valid to VCC = 1V
—Monitor three voltages or detect power fail
• Independent Core Voltage Monitor (V2MON)
• Fault detection register
• Selectable power on reset timeout (0.05s,
0.2s, 0.4s, 0.8s)
• Selectable watchdog timer interval (25ms, 200ms,
1.4s, off)
• Low power CMOS
—25µA typical standby current, watchdog on
—6µA typical standby current, watchdog off
• 400kHz 2-wire interface
• 2.7V to 5.5V power supply operation
• Available packages
—8-lead SOIC, TSSOP
APPLICATIONS
• Communication Equipment
—Routers, Hubs, Switches
—Disk Arrays, Network Storage
• Industrial Systems
—Process Control
—Intelligent Instrumentation
• Computer Systems
— Computers
—Network Servers
DESCRIPTION
The X40010/11/14/15 combines power-on reset con-
trol, watchdog timer, supply voltage supervision, and
secondary voltage supervision, in one package. This
combination lowers system cost, reduces board space
requirements, and increases reliability.
Applying voltage to VCC activates the power on reset
circuit which holds RESET/RESET active for a period of
time. This allows the power supply and system oscillator
to stabilize before the processor can execute code.
Low VCC detection circuitry protects the user’s system
from low voltage conditions, resetting the system when
VCC falls below the minimum VTRIP1 point. RESET/
RESET is active until VCC returns to proper operating
level and stabilizes. A second voltage monitor circuit
tracks the unregulated supply to provide a power fail
warning or monitors different power supply voltage.
Three common low voltage combinations are avail-
able, however, Xicor’s unique circuits allows the
BLOCK DIAGRAM
SDA
SCL
VCC
(V1MON)
V2MON
Data
Register
Command
Decode Test
& Control
Logic
Threshold
Reset Logic
Fault Detection
Register
Status
Register
Watchdog Timer
and
Reset Logic
User Programmable
VTRIP1
User Programmable
VTRIP2
+
-
V2MON
+ VCC
Power on,
Low Voltage
Reset
Generation
-
*X40010/11 = V2MON*
X40014/15 = VCC
WDO
RESET
X40010/14
RESET
X40011/15
V2FAIL
REV 1.3.4 7/12/02
www.xicor.com
Characteristics subject to change without notice. 1 of 25









No Preview Available !

X40011S8I-B Даташит, Описание, Даташиты
X40010/X40011/X40014/X40015 – Preliminary
threshold for either voltage monitor to be repro-
grammed to meet special needs or to fine-tune the
threshold for applications requiring higher precision.
The Watchdog Timer provides an independent protec-
tion mechanism for microcontrollers. When the micro-
controller fails to restart a timer within a selectable time
out interval, the device activates the WDO signal. The
user selects the interval from three preset values. Once
selected, the interval does not change, even after
cycling the power.
The device features a 2-wire interface and software
protocol allowing operation on an I2C® bus.
Dual Voltage Monitors
Device
X40010/11
-A
-B
-C
X40014/15
-A
-B
-C
Expected System Voltages
5V; 3V or 3.3V
5V; 3V
3V; 3.3V; 1.8V
3V; 3.3V; 1.5V
3V; 1.5V
3V or 3.3V; 1.1 or 1.2V
Vtrip1(V)
2.0–4.75*
4.55–4.65*
4.35–4.45*
2.85–2.95*
2.0–4.75*
2.85–2.95*
2.55–2.65*
2.85–2.95*
*Voltage monitor requires VCC to operation. Others are independent of VCC.
Vtrip2(V)
1.70–4.75
2.85–2.95
2.55–2.65
1.65–1.75
0.90–3.50*
1.25–1.35*
1.25–1.35*
0.95–1.05*
POR (system)
RESET = X40010
RESET = X40011
RESET = X40014
RESET = X40015
PIN CONFIGURATION
X40010/14, X40011/15
8-Pin SOIC
V2FAIL 1
V2MON 2
8 VCC
7 WDO
RESET/RESET
VSS
3
4
6 SCL
5 SDA
X40010/14, X40011/15
8-Pin TSSOP
WDO
VCC
V2FAIL
V2MON
1
2
3
4
8 SCL
7 SDA
6 VSS
5 RESET/RESET
PIN DESCRIPTION
Pin
SOIC TSSOP Name
Function
1 3 V2FAIL V2 Voltage Fail Output. This open drain output goes LOW when V2MON is less than VTRIP2 and
goes HIGH when V2MON exceeds VTRIP2. There is no power up reset delay circuitry on this pin.
2 4 V2MON V2 Voltage Monitor Input. When the V2MON input is less than the VTRIP2 voltage, V2FAIL goes
LOW. This input can monitor an unregulated power supply with an external resistor divider or can
monitor a second power supply with no external components. Connect V2MON to VSS or VCC
when not used.The V2MON comparator is supplied by V2MON (X40010/11) or by VCC Input
(X40014/15).
3 5 RESET/ RESET Output. (X40011/15) This is an active LOW, open drain output which goes active when-
RESET ever VCC falls below VTRIP1. It will remain active until VCC rises above VTRIP1 and for the tPURST
thereafter.
RESET Output. (X40010/14) This is an active HIGH CMOS output which goes active whenever
VCC falls below VTRIP1. It will remain active until VCC rises above VTRIP1 and for the tPURST there-
after.
4 6 VSS Ground
REV 1.3.4 7/12/02
www.xicor.com
Characteristics subject to change without notice. 2 of 25









No Preview Available !

X40011S8I-B Даташит, Описание, Даташиты
X40010/X40011/X40014/X40015 – Preliminary
PIN DESCRIPTION (Continued)
Pin
SOIC TSSOP
57
68
71
82
Name
SDA
SCL
WDO
VCC
Function
Serial Data. SDA is a bidirectional pin used to transfer data into and out of the device. It has an
open drain output and may be wire ORed with other open drain or open collector outputs. This pin
requires a pull up resistor and the input buffer is always active (not gated).
Watchdog Input. A HIGH to LOW transition on the SDA (while SCL is toggled from HIGH to
LOW and followed by a stop condition) restarts the Watchdog timer. The absence of this tran-
sition within the watchdog time out period results in WDO going active.
Serial Clock. The Serial Clock controls the serial bus timing for data input and output.
WDO Output. WDO is an active LOW, open drain output which goes active whenever the
watchdog timer goes active.
Supply Voltage
PRINCIPLES OF OPERATION
Power On Reset
Application of power to the X40010/11/14/15 activates a
Power On Reset Circuit that pulls the RESET/RESET
pins active. This signal provides several benefits.
– It prevents the system microprocessor from starting to
operate with insufficient voltage.
– It prevents the processor from operating prior to stabili-
zation of the oscillator.
– It allows time for an FPGA to download its configuration
prior to initialization of the circuit.
– It prevents communication to the EEPROM, greatly
reducing the likelihood of data corruption on power up.
When VCC exceeds the device VTRIP1 threshold value for
tPURST (selectable) the circuit releases the RESET
(X40011) and RESET (X40010) pin allowing the system
to begin operation.
Low Voltage VCC (V1 Monitoring)
During operation, the X40010/11/14/15 monitors the VCC
level and asserts RESET/RESET if supply voltage falls
below a preset minimum VTRIP1. The RESET/RESET
signal prevents the microprocessor from operating in a
power fail or brownout condition. The V1FAIL signal
remains active until the voltage drops below 1V. It also
remains active until VCC returns and exceeds VTRIP1 for
tPURST.
Low Voltage V2 Monitoring
The X40010/11/14/15 also monitors a second voltage
level and asserts V2FAIL if the voltage falls below a
preset minimum VTRIP2. The V2FAIL signal is either
ORed with RESET to prevent the microprocessor from
operating in a power fail or brownout condition or used to
interrupt the microprocessor with notification of an
impending power failure. For the X40010/11 the V2FAIL
signal remains active until the VCC drops below 1V (VCC
falling). It also remains active until V2MON returns and
exceeds VTRIP2 by 0.2V. This voltage sense circuitry
monitors the power supply connected to the V2MON pin.
If VCC = 0, V2MON can still be monitored.
For the X40014/15 devices, the V2FAIL signal remains
actice until VCC drops below 1Vx and remains active until
V2MON returns and exceeds VTRIP2. This sense circuitry
is powered by VCC. If VCC = 0, V2MON cannot be moni-
tored.
Figure 1. Two Uses of Multiple Voltage Monitoring
X40011-A
VCC V2MON
6–10V
1M
1M
5V VCC
Reg RESET
V2MON
(2.9V)
V2FAIL
System
Reset
Resistors selected so 3V appears on V2MON when unregulated
supply reaches 6V.
Unreg.
Supply
3.3V
Reg
1.2V
Reg
X40014-C
VCC
VCC
RESET
V2MON
V2FAIL
System
Reset
Notice: No external components required to monitor two voltages.
REV 1.3.4 7/12/02
www.xicor.com
Characteristics subject to change without notice. 3 of 25










Скачать PDF:

[ X40011S8I-B.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
X40011S8I-ADual Voltage Monitor with Integrated CPU SupervisorXicor
Xicor
X40011S8I-BDual Voltage Monitor with Integrated CPU SupervisorXicor
Xicor
X40011S8I-CDual Voltage Monitor with Integrated CPU SupervisorXicor
Xicor

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |

  Контакты    |    Поиск