DataSheet26.com

AC101L PDF даташит

Спецификация AC101L изготовлена ​​​​«ETC» и имеет функцию, называемую «10 / 100 BASE-TX SINGLE-PHY TRANSCEIVER».

Детали детали

Номер произв AC101L
Описание 10 / 100 BASE-TX SINGLE-PHY TRANSCEIVER
Производители ETC
логотип ETC логотип 

5 Pages
scroll

No Preview Available !

AC101L Даташит, Описание, Даташиты
D AC Types Feature 1.5-V to 5.5-V Operation
and Balanced Noise Immunity at 30% of the
Supply Voltage
D Speed of Bipolar F, AS, and S, With
Significantly Reduced Power Consumption
D Balanced Propagation Delays
D ±24-mA Output Drive Current
– Fanout to 15 F Devices
D SCR-Latchup-Resistant CMOS Process and
Circuit Design
D Exceeds 2-kV ESD Protection Per
MIL-STD-883, Method 3015
CD54AC05, CD74AC05
HEX INVERTERS
WITH OPEN-DRAIN OUTPUTS
SCHS306C – JANUARY 2001 –REVISED JUNE 2002
CD54AC05 . . . F PACKAGE
CD74AC05 . . . E OR M PACKAGE
(TOP VIEW)
1A
1Y
2A
2Y
3A
3Y
GND
1
2
3
4
5
6
7
14 VCC
13 6A
12 6Y
11 5A
10 5Y
9 4A
8 4Y
description
The ’AC05 devices contain six independent inverters. These devices perform the Boolean function Y = A. The
open-drain outputs require pullup resistors to perform correctly, and can be connected to other open-drain
outputs to implement active-low wired-OR or active-high wired-AND functions.
ORDERING INFORMATION
TA
PACKAGE†
ORDERABLE
PART NUMBER
TOP-SIDE
MARKING
PDIP – E Tube
CD74AC05E
CD74AC05E
Tube
–55°C to 125°C SOIC – M
Tape and reel
CD74AC05M
CD74AC05M96
AC05M
CDIP – F Tube
CD54AC05F3A CD54AC05F3A
Package drawings, standard packing quantities, thermal data, symbolization, and PCB
design guidelines are available at www.ti.com/sc/package.
FUNCTION TABLE
(each inverter)
INPUT
A
OUTPUT
Y
HL
LZ
logic diagram, each inverter (positive logic)
AY
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
Copyright 2002, Texas Instruments Incorporated
On products compliant to MIL-PRF-38535, all parameters are tested
unless otherwise noted. On all other products, production
processing does not necessarily include testing of all parameters.
1









No Preview Available !

AC101L Даташит, Описание, Даташиты
CD54AC05, CD74AC05
HEX INVERTERS
WITH OPEN-DRAIN OUTPUTS
SCHS306C JANUARY 2001 REVISED JUNE 2002
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to 6 V
Input clamp current, IIK (VI < 0 or VI > VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA
Output clamp current, IOK (VO < 0 or VO > VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA
Package thermal impedance, θJA (see Note 2): E package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80°C/W
M package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86°C/W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C
Stresses beyond those listed under absolute maximum ratingsmay cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditionsis not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions (see Note 3)
TA = 25°C
MIN MAX
40°C TO
85°C
MIN MAX
55°C TO
125°C
MIN MAX
UNIT
VCC Supply voltage
1.5 5.5 1.5 5.5 1.5 5.5 V
VCC = 1.5 V
1.2 1.2 1.2
VIH High-level input voltage
VCC = 3 V
2.1 2.1 2.1 V
VCC = 5.5 V
3.85 3.85 3.85
VCC = 1.5 V
0.3 0.3 0.3
VIL Low-level input voltage
VCC = 3 V
0.9 0.9 0.9 V
VCC = 5.5 V
1.65 1.65 1.65
VI Input voltage
0 VCC
0 VCC
0 VCC V
VO Output voltage
0 5.5
0 5.5
0 5.5 V
IOH High-level output current
VCC = 4.5 V to 5.5 V
24 24 24 mA
IOL Low-level output current
VCC = 4.5 V to 5.5 V
24 24 24 mA
t/v Input transition rise or fall rate
VCC = 1.5 V to 3 V
VCC = 3.6 V to 5.5 V
50 50 50
ns/V
20 20 20
NOTE 3: All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
2 POST OFFICE BOX 655303 DALLAS, TEXAS 75265









No Preview Available !

AC101L Даташит, Описание, Даташиты
CD54AC05, CD74AC05
HEX INVERTERS
WITH OPEN-DRAIN OUTPUTS
SCHS306C JANUARY 2001 REVISED JUNE 2002
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25°C
MIN MAX
40°C TO
85°C
MIN MAX
55°C TO
125°C
MIN MAX
UNIT
1.5 V
0.1 0.1 0.1
IOL = 50 µA
3V
4.5 V
0.1 0.1 0.1
0.1 0.1 0.1
VOL
VI = VIH or VIL
IOL = 12 mA
3V
0.36 0.44
0.5 V
IOL = 24 mA
IOL = 50 mA
IOL = 75 mA
4.5 V
5.5 V
5.5 V
0.36 0.44
0.5
1.65
1.65
II VI = VCC or GND
5.5 V
±0.1
±1
±1 µA
ICC
VI = VCC or GND,
IO = 0
5.5 V
4 40 80 µA
Ci 10 10 10 pF
Test one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage to minimize
power dissipation. Test verifies a minimum 50-transmission-line drive capability at 85°C and 75-transmission-line drive capability at 125°C.
switching characteristics over recommended operating free-air temperature range,
VCC = 1.5 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
40°C TO
85°C
MIN MAX
55°C TO
125°C
MIN MAX
tPLZ
tPZL
A
94 103
Y
74 81
UNIT
ns
switching characteristics over recommended operating free-air temperature range,
VCC = 3.3 V ± 0.3 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
40°C TO
85°C
MIN MAX
55°C TO
125°C
MIN MAX
tPLZ
tPZL
A
3 10.4 2.9 11.5
Y
2.3 8.3 2.3 9.1
UNIT
ns
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V ± 0.5 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
40°C TO
85°C
MIN MAX
55°C TO
125°C
MIN MAX
tPLZ
tPZL
A
2.2 7.5 2.1 8.2
Y
1.7 5.9 1.6 6.5
UNIT
ns
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd Power dissipation capacitance
TYP UNIT
105 pF
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3










Скачать PDF:

[ AC101L.PDF Даташит ]

Номер в каталогеОписаниеПроизводители
AC101NF TriodeTELEFUNKEN
TELEFUNKEN
AC101-QF10/100 BASE - TX SINGLE-CHANNEL ALTI PHY TRANSCEIVERAltima
Altima
AC101-TF10/100 BASE - TX SINGLE-CHANNEL ALTI PHY TRANSCEIVERAltima
Altima
AC101910 TO 1000 MHz TO-8 CASCADABLE AMPLIFIERETC
ETC

Номер в каталоге Описание Производители
TL431

100 мА, регулируемый прецизионный шунтирующий регулятор

Unisonic Technologies
Unisonic Technologies
IRF840

8 А, 500 В, N-канальный МОП-транзистор

Vishay
Vishay
LM317

Линейный стабилизатор напряжения, 1,5 А

STMicroelectronics
STMicroelectronics

DataSheet26.com    |    2020    |